Planning Information
Model CT36G 36"
(914)
Gas Cooktop
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, cut-out dimensions and
installation specifics.
Wolf recommends using 39" (991) wide
cabinets with the 36" (914) cooktop.
A Wolf downdraft system, Cooktop or Pro
ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to the countertop. Also refer to
Ventilation Recommendations in the Cooktop
Ventilation or Pro Ventilation sections of our
website, wolfappliance.com.
The Wolf 36" (914) gas cooktop requires a
separate 120 V AC, 60 Hz power supply. The
service should have its own 15 amp circuit
breaker and a grounded 3-prong receptacle
should be located within the reach of the
6' (1.8 m) power cord. Locate electrical within
the shaded area shown in the Installation
Specifications illustration on page 4.
IMPORTANT NOTE:
A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
When a gas cooktop is installed above
cabinets, placement of the electrical and gas
supply is not critical. A grounded outlet needs
to be placed within 4' (1.2 m) of the right rear
of the cooktop.
A Wolf 36" (914) or 30" (762) built-in single
oven may be installed below this cooktop. For
this installation, the electrical and gas supply
for the cooktop should be installed in the
adjacent cabinet. Refer to page 6 for additional
specifications. Be aware of the depth of the
cooktop when planning for this installation.
IMPORTANT NOTE:
Wolf gas cooktops are
designed and agency approved for installation
with Wolf built-in ovens only.
IMPORTANT NOTE:
When a oven is installed
below the cooktop, unless you are using
cabinets deeper than 24" (610), it is recom-
mended that the electrical supply for the oven
be placed in an adjacent cabinet within reach of
the conduit. A 2" (51) diameter hole to route the
conduit through cabinetry will be required. Refer
to page 6 for location of electrical supply and
additional specifications.
When a 36" (914) oven is installed below a
cooktop, it is recommended that the rough
opening for the oven be 7
3
/
4
" (197) from the
floor to ease the use of the oven door. The
bottom cabinet support must be able to support
250 lbs (113 kg).
Wolf gas cooktops are designed to operate
on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP (propane) gas at 10" (25
mb) WC pressure. The minimum line pressure
for natural gas is 7" (17.5 mb) WC and 11"
(27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa). The
cooktops are supplied with a
1
/
2
" NPT male gas
connection at the right rear bottom corner of
the cooktop. The male connector exits the unit
straight down and you are supplied with a
regulator with two female connectors.
Wolf gas cooktops using natural gas
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
When multiple cooktop units are installed
side by side, refer to the countertop cut-out
dimensions on page 7.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.
This cooktop is intended for indoor use only.