Wolf CSO24TE Скачать руководство пользователя страница 3

wolfappliance.com   

|

   3

CONVECTION STEAM OVEN

Product Information

Important product information including the model and 
serial number are listed on the product rating plate. The 
rating plate is located on the left side of the front face frame. 
The oven door must be open to view the rating plate. Refer 
to the illustration below.

If service is necessary, contact Wolf Factory Certified 
Service with the model and serial number. For the name of 
the nearest Wolf Factory Certified Service or for questions 
regarding the installation, visit the contact & support section 
of our website, wolfappliance.com, or call Wolf Customer 
Care at 800-222-7820.

 
Rating plate location.

 

RATING PLATE

Installation Requirements

The convection steam oven can be installed in a standard 
or flush inset application. The electrical supply for the oven 
must be located in an adjacent cabinet.

Finish the edges of the opening. They may be visible when 
the door is open.

For standard installations, face trim will overlap stiles and 
rails. Refer to the chart.

For flush inset installations, a minimum 

1

/

8

"

 (3)

 reveal is 

required on all sides. To ensure consistent reveals, each 
corner of the opening must be exactly 90°.

If the convection steam oven is installed above or below 
a Wolf E series oven in a flush inset application, a 

1

/

4

"

 (6)

 

reveal is required.

INSTALLATION REQUIREMENTS

BASE SUPPORT

MIN

Convection Steam Oven

100 lb

 (45 kg)

TRIM OVERLAP

24" MODEL

30" MODEL

Top

3

/

16

"

 (5)

3

/

16

"

 (5)

Bottom

0"

 (0)

0"

 (0)

Sides

11

/

16

"

 (18) 

3

7

/

8

"

 (98)

Содержание CSO24TE

Страница 1: ...CONVECTIO N ST EAM O VEN INSTALLATION GUIDE SP E CI FI CATI O NS INSTALLATION AND MORE...

Страница 2: ...here minor injury or product damage may occur if instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed IMPORTANT NOTE Throughout...

Страница 3: ...Rating plate location RATING PLATE Installation Requirements The convection steam oven can be installed in a standard or flush inset application The electrical supply for the oven must be located in a...

Страница 4: ...plug clearance Performance may be compromised if the electrical supply is less than 240 volts ELECTRICAL REQUIREMENTS Electrical Supply grounded 240 208 VAC 60 Hz Service 20 amp dedicated circuit Rece...

Страница 5: ...SIDE VIEW NOTE 24 610 and 30 762 models require the same opening dimensions Electrical supply must be located in adjacent cabinet within 3 9 m of opening 1711 16 449 OPENING HEIGHT 219 16 548 OPENING...

Страница 6: ...FLUSH INSET DEPTH 7 8 22 Will be visible and should be finished to match cabinetry Dimension provides minimum reveals NOTE Electrical supply must be located in adjacent cabinet within 3 9 m of opening...

Страница 7: ...wer is supplied to the oven Verify proper electrical connections If the oven does not operate properly contact Wolf Factory Certified Service Do not attempt to repair the oven Wolf is not responsible...

Страница 8: ...se pueden sufrir heridas leves o provocar da os al producto si no se siguen las instrucciones ADVERTENCIA indica peligro de que se produzcan heridas graves o incluso la muerte si no se siguen las prec...

Страница 9: ...a de datos PLACA DE DATOS Requisitos de instalaci n El horno de vapor de convecci n se puede instalar en una aplicaci n est ndar o empotrable Se requiere una base de soporte m nima de 100 libras 45 kg...

Страница 10: ...s ya que puede interrumpir el funcionamiento de la unidad El rendimiento puede verse comprometido si el suministro el ctrico es menor a 240 voltios REQUISITOS EL CTRICOS Suministro el ctrico Con cone...

Страница 11: ...ministro el ctrico debe estar en un gabinete adyacente a 3 pies 0 9 m de la abertura 1711 16 449 ALTURA DE LA ABERTURA 219 16 548 PROFUNDIDAD DE LA ABERTURA VISTA SUPERIOR W ANCHO DE ABERTURA E E ESPE...

Страница 12: ...W ANCHO DE LA INSTALACI N EMPOTRABLE FRONT VIEW VISTA LATERAL 23 584 PROFUNDIDAD DE LA INSTALACI N EMPOTRABLE 7 8 22 Ser visible y debe tener un acabado que haga juego con los gabinetes Dimensi n m ni...

Страница 13: ...correctas Si el horno no funciona correctamente p ngase en contacto con el centro de servicio autorizado de Wolf No intente reparar el horno Wolf no es responsable del servicio necesario para corregir...

Страница 14: ...une blessure mineure ou des dommages au produit peuvent se produire si les directives ne sont pas respect es AVERTISSEMENT d crit un danger qui peut causer une blessure grave ou la mort si les pr caut...

Страница 15: ...l tique PLAQUE SIGNAL TIQUE Exigences d installation Le four convection et vapeur peut tre install dans une application standard ou affleur e Un support de base minimum de 100 lb 45 kg est requis L al...

Страница 16: ...et peut interrompre le fonctionnement La performance peut tre compromise si l alimentation lectrique est inf rieure 240 volts EXIGENCES LECTRIQUES Alimentation lectrique mise la terre 240 208 volts C...

Страница 17: ...o 221 8 po 562 VUE DE FACE VUE DE PROFIL REMARQUE les mod les 24 po 610 mm et 30 po 762 mm n cessitent les m mes dimensions d ouverture L alimentation lectrique doit se trouver dans une armoire adjace...

Страница 18: ...Dimension fournit minimum r v le REMARQUE l alimentation lectrique doit se trouver dans une armoire adjacente moins de 3 pieds 90 cm de l ouverture 181 8 po 460 HAUTEUR DE L AFFLEUREMENT 5 16 po 8 1 8...

Страница 19: ...iques Si le four ne fonctionne pas correctement communiquez avec le centre service Wolf certifi par l usine Ne tentez pas de r parer le four Wolf n est pas responsable du service requis pour corriger...

Страница 20: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 9015787 REV A 8 2017...

Отзывы: