NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39080 (04-07)
Model CMJ Series
Gas Infrared Cheesemelter
INSTALLATION REQUIREMENTS:
1. A gas pressure regulator sized for this unit is included.
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas line connecting to appliance must be ¾" diameter or
larger. If flexible connectors are used, the inside diameter
must be the same as the ¾" iron pipe.
3. An adequate ventilation system is required for commer-
cial cooking equipment. Information may be obtained
by writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American
Gas Association, Accredited Standards Committee Z223
MODEL
NUMBER OF
TOTAL
APPROX. SHP.
NO.
WIDTH
DEPTH
HEIGHT
BURNERS
BTU/hr.
WT. (lbs./kg)
CMJ24
24"
20½"
19
¹⁄₁₆
"
1
18,000
106/48
CMJ34
34"
20½"
19
¹⁄₁₆
"
1
24,000
159/72
CMJ36
36"
20½"
19
¹⁄₁₆
"
1
24,000
159/72
CMJ48
48"
20½"
19
¹⁄₁₆
"
2
36,000
212/95
CMJ60
60"
20½"
19
¹⁄₁₆
"
2
42,000
265/119
CMJ72
72"
20½"
19
¹⁄₁₆
"
2
48,000
318/143
@ 400N. Capital St. NW, Washington, DC 20001, or the
Secretary Standards Council, NFPA, 1 Batterymarch Park,
Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power
means of exhaust shall comply with 248 CMR.
5. Clearances:
Combustible
Non-Combustible
Rear
2"
0"
Sides
20"
0"
Bottom
10"
4"