SURFACE BURNER VALVES
1
Remove the skirt.
2
Remove the door(s).
3
Remove the collar(s).
4
Remove the burner knobs and bezels.
5
Remove the bullnose.
6
Remove two 6-lobe screws from each bezel
receptacle, then remove the receptacle from the
valves.
7
For the 20,000 Btu (5.9 kW), 18,000 Btu (5.3 kW),
and 15,000 Btu (3.5 kW) burner valves, remove the
main and simmer bypass orifices and replace with
new '67' main and '62' simmer orifices.
For the 9,200 Btu (2.7 kW) burner valve, remove the
main and simmer bypass orifices and replace with
new '54' main and '50' simmer orifices.
8
For charbroiler and French top models, remove the
orifice and replace with a new '1F' orifice.
FRENCH TOP
1
Remove the center plate, burner head bracket and
burner cap, then remove two screws from the burner.
2
Gently lift the burner, then disconnect the ignitor wire.
Set burner assembly aside.
3
Remove the existing main orifice and replaced with a
new '180'.
GRIDDLE AND CHARBROILER
1
For a griddle, remove the existing orifice and replace
the griddle with a new '51' orifice.
2
For a charbroiler, remove the existing orifice and
replace with a new '50' orifice.
REGULATOR CONVERSION
1
Use a flat blade screwdriver to rotate the regulator
cap, then remove the cap.
2
Flip the cap over and install. 'NAT' appears on the
cap when properly converted.
Dual Fuel Range Conversion to Natural Gas
Installation
www.subzero-wolf.com 800.222.7820
Page 2 of 3