ended or been cancelled with the C I/O key the cursor flashes at Pre-assess-
ment on the display and the results can be viewed in turn at each press of the
± key
as follows:
Difference: 54.4 hPa
± key
Start pressure: 1000.3 hPa
± key
Time: 10.00
± key
Stop pressure: 945.9 hPa
± key
Text: “Print …” (activate the printout with the ENTER key)
± key
Difference: 54.4 hPa
etc.
These results can also be printed out or transferred to a PC at a later time
under the menu item Print or
Log/IR
respectively. By default, the print-out
includes a grafic of the pressure progression. You can disable this function
under the item „grafic“.
The record is not deleted until the logger is started or another TRGI test is
conducted.