GMG-LEZ Operation manual
Page 37 of 37
B0840
11.3 Control settings parameter sheet
Pump unit no.:
Menu item
Possible
setting
Setting
Factory
setting
P1
Selection between time and pulse mode
Time 001
Pulse 002
1
P2
Cycle time setting in hours in time mode
0
… 255
0
P3
Cycle time setting in minutes in time mode
0
… 59
2
P4
External machine pulse setting in pulse mode
1
… 9999
5
P5
Operate half cycle (only one rotating direction) and
full cycle (both rotation directions)
half = 01
full = 02
2
P6
Cycle number setting only for full cycle
1
… 999
1
P7
Settings for overtravel time after pressure switch
signal in minutes
0 … 59
0
P8
Monitoring period setting for the pressure switches
in minutes
1
… 59
5
P9
Settings of end signal. Do not transmit end signal
or transmit end signal. (Interruption alarm output 1
second)
No = 01
Yes = 02
1
P10 Relief time in seconds to relieve the pressure line
1 … 59
3
P11 Stirring on or off
Off = 000
On = 001
000
P12 Off-duty time setting for stirring in hours
1 … 100
1