background image

SDC107 –DC motor driver  user manual                    

www.wobit.com.pl

      

10 

 

4

 

Problems and solutions 

 

The motor does not 
revolve  

1) Check if the green POWER LED is on. If not - no power supply to the driver or 
damaged driver. 
2) Check if a signal is given to the ENABLE input. 
3) Check if the LIMIT LED is flashing. If so, it means that the limit input is active 
(chapter 3.4) 
4) Check if the red ERR LED is flashing. If so, it means the driver is 
in error mode. To clear the error, remove and re-enter the ENABLE signal. 
5) Check the configuration of the S1 / S2 switches (chapter 3.1).  
6) If external control is active, check that the control voltage has been applied 
(0..5 V).  

The driver signals an 
error after changing the 
direction of rotation or 
switching on. 

The motor starting current is too high. The driver signals when the max current is 
reached or goes into error mode (the ERROR LED flashes). It is recommended to 
enable the SOFT-START function (switch S3 = ON). 

The driver signals an 
error during braking. 

For the active BRAKE-STOP S4 = ON mode, braking returns energy from the 
motor to the power supply, which may increase the power supply voltage. If the 
power supply is not able to receive such energy (too small electrolytic capacitors 
at the power output), the driver supply voltage may exceed the max. value (40 
V). Then the driver will go into error condition. 

The driver signals an 
error as soon as the 
ENABLE signal is 
activated. 

Check for a short circuit between motor leads or between the M + or M- signal 
and GND or VDC. 
If the error repeats and cannot be cleared, the driver has been damaged. 

The motor is spinning 
slowly, the red LED is 
on. 

The motor current limit is active. Check the configuration of the S1 switches 
and S2 and depending on the set mode, increase the current limit with the built-
in potentiometer or an external 0-5V signal. 

 

 

5

 

Technical parameters 

 

 

Mechanical parameters 

Housing dimensions: 

101 x 18 x 80 mm 

Weight: approx. 

100 g 

Operating temperature 
range: 

5..50 °C 

Protection degree: 

IP20 

Mounting 

DIN rail 

 
 
 

 
 
 
 

18 

Содержание SDC107

Страница 1: ...K J Ober s c 62 045 Pniewy D borzyce 16 tel 61 22 27 422 fax 61 22 27 439 e mail wobit wobit com pl www wobit com pl User manual SDC107 DC motor driver up to 6A With speed current and direction of rot...

Страница 2: ...and solutions 10 5 Technical parameters 10 Thank you for selecting our product This instruction will help you at correct service and accurate exploitation of described device Information included in t...

Страница 3: ...les of protection against the threats mentioned above provided that the device is used in a manner consistent with its purpose and that it is properly maintained The device can cause interference of s...

Страница 4: ...tion using 6 switches on the front panel of the driver 5 V output for supplying an external potentiometer Optoisolated inputs for the activation ENABLE the direction DIR signals and the limit LIM N LI...

Страница 5: ...driver it is recommended to use a power supply with an output voltage equal to the rated voltage of the motor used in the range of 12 36 V and current capacity appropriate to the motor power In the c...

Страница 6: ...Activation of speed control from the internal potentiometer S2 POT MODE Current limit mode S3 SOFT START Soft start function S4 BRAKE STOP Braking function in the absence of ENABLE signal and limit si...

Страница 7: ...soft start of the motor the delay in reaching the maximum speed is about 2 seconds Activation of the function may be necessary when controlling motors with more power or driving mechanisms with greate...

Страница 8: ...used When S5 OFF it is for NO Normal Open sensors when S5 ON it is NC Normal Close sensors For 3 wire applications e g inductive use sensors with PNP output When using sensors with NPN output the LIM...

Страница 9: ...signal input to ENABLE The motor moves in the direction depending on the signal at the DIR input After reaching the extreme position and activating the LIMIT N or P sensor the motor stops for about 3...

Страница 10: ...OFT START function switch S3 ON The driver signals an error during braking For the active BRAKE STOP S4 ON mode braking returns energy from the motor to the power supply which may increase the power s...

Страница 11: ...5 V 5 V max current consumption 100 mA Max Motor constant current 6 A Analog input 0 5 V IN 0 5 V input resistance 4 4k ohm Control inputs ENABLE DIR LIMIT N LIMIT P Optoinsulated low level 2 V high...

Отзывы: