Product User Manual
□ Normal □ Internal Use
Confidential □ Restricted Confidential
11 / 36
1.3 Connection Interface
The IMA2 module is an LGA device. All electrical and mechanical connections are
made through the 80 pads on the bottom side of the PCB.
1.4 Environmental Specifications
and
Certifications
1.4.1 Environmental Specifications
The environmental specifications for both operating and storage conditions are
defined in the table below.
Condition
Temperature Range Remark
Normal ambient
operating temp. range
–20 °C to 60 °C Fully functional and complies with 3GPP
specifications
Extended ambient
operating temp. range
–40 °C to 85°C (TBD)
RF performance may be affected outside normal
ambient operating range temp., although the
module will still function.
Storage
–40 °C to 85 °C
Table 1-5. Temperature range
1.4.2 Certifications
The IMA2 module is compliant with the following regulations: PTCRB, FCC, IC, and
AT&T TA.
1.4.3 Green Product Compliance
RoHS (2011/65/EU)