W7500S2E serial to Ethernet module 

W7500S2E user manual 

43 

7.2

 

Basic Settings 

Figure below shows W7500S2E basic settings page. It separates into four sections. 
On each screen, you may need to click “Save Settings” before you move onto the next screen. 
After  you've  done  that,  you  may  click  “Reset”  to  reset  the  module  for  the  settings  to  be 
applied.   
Please know that the session time for the W7500S2E webserver is 5 minutes. After 5 minutes 
of inactivity, re-login is required. 

 

Figure 7-3 Basic Settings page 

Network Setting 

Setting 

Description 

Default 

MAC Address: 

MAC address of the module 

Not configurable   

Use DHCP: 

DHCP mode option 

Disable (uncheck) 

IP address: 

IP address of the module 

192.168.1.88 

Subnet Mask: 

Subnet Mask 

255.255.255.0 

Gateway: 

Gateway 

192.168.1.1 

DNS Server: 

DNS server IP address 

114.114.114.114 

Socket Setting 

Setting 

Description 

Default 

Start mode: 

“AT Command Mode” or “Data pass-through mode” 

“AT Command Mode” 

Socket Type: 

“TCP Server”, “TCP Client” or “UDP mode” 

“TCP Server” 

Содержание W7500S2E Series

Страница 1: ...485 transceiver Flexible data packet condition for the serial interface Support DHCP to configure IP address and other network configuration parameters Support DNS for remote server domain name looku...

Страница 2: ...and 3 3 Revised structure of documentation V1 1 2019 02 19 Add new Data transfer command Revised structure of documentation Remove obsolete information Updated all images V1 1 1 2019 03 19 Move Facto...

Страница 3: ...pass through mode 13 5 WIZS2E ConfigTool 13 5 1 Reading module information 13 5 2 Modify the device settings 14 5 3 Reset the module 14 5 4 Useful features 14 6 Introduction of AT command 16 6 1 AT co...

Страница 4: ...3 Voltage input DC 3 3V 4 Operating temperature 40 C 85 C W7500S2E C1 1 W7500 MCU integrated with W7500S2E firmware 2 Operating temperature 40 C 85 C 3 For hardware details please visit the W7500 web...

Страница 5: ...trical characteristics VIN 3 3V Table 1 3 W7500S2E Z1 electrical characteristics VIN 5 0V Symbol Types Ratings Min Typical Max Unit VIN Module voltage 4 4 5 0 6 0 V IIN Module current 75 66 55 mA Curr...

Страница 6: ...Please refer to the figure below which shows the dimension of the module W7500S2E Z1 layout and dimension Figure 1 1 W7500S2E Z1 dimension top view Figure 1 2 W7500S2E Z1 dimension side view A power L...

Страница 7: ...module W7500S2E user manual 4 W7500S2E R1 layout and dimension Figure 1 3 W7500S2E R1 dimension top view Figure 1 4 W7500S2E R1 dimension side view A power LED locates on the top of each module with...

Страница 8: ...D O UART TXD signal 7 RXD I UART RXD signal 8 RTS O UART flow control RTS signal 485EN O Configurable as 485 enable pin This function is supported by firmware version is 2 2 or above 9 DEFAULT I Facto...

Страница 9: ...l 485EN O Configurable as 485 enable pin This function is supported by firmware version is 2 2 or above 9 DEFAULT I Factory reset pin pull down over 3s 10 RESET I Reset pin pull down over 200ms 11 GND...

Страница 10: ...OP 3 TXON 7 4 8 P2 interface pin Assignment Pin Signal Pin Signal 1 5V 5 3V3 2 GND 6 GND 3 TX 7 RTS 4 RX 8 CTS The mini USB Interface J6 pin assignment Note This mini USB connector is only for the pow...

Страница 11: ...button over 3 seconds for factory reset SW2 RESET Hardware reset button WIZS2E breakout board LED description Table 2 4 WIZS2E breakout board LED description LED Description ACT Ethernet ACT indicato...

Страница 12: ...W7500S2E serial to Ethernet module W7500S2E user manual 9 2 W7500S2E R1 reference schematic Figure 2 5 W7500S2E R1 reference schematic...

Страница 13: ...ser manual 10 2 3 Quick testing guide WIZS2E module can convert any devices with serial interface to have Ethernet connectivity easily Figure 2 6 W7500S2E module testing evaluation block diagram TCP I...

Страница 14: ...ished 3 2 TCP client mode Figure 3 2 TCP client mode diagram In TCP client mode W7500S2E connects to a preset TCP server If failure to connect it can be configured to re connect continuously They can...

Страница 15: ...s 4 If the TCP connection is closed module will act as below In TCP server mode it will listen on a local port again and wait for a TCP client connection In TCP client mode it will reconnect to the pr...

Страница 16: ...r details please refer to chapter 5 5 WIZS2E ConfigTool WIZS2E ConfigTool is Windows software compatibles to all WIZS2E modules It can be used to read configure all settings and firmware updating for...

Страница 17: ...your configuration and restart 5 3 Reset the module First click the Reset button and then to click the Reset Now button to reset the module without saving any setting 5 4 Useful features Switching PC...

Страница 18: ...the list on the left side the function list will appear as shown in the figure below 1 Expand collapse all device details 2 The device list can be sorted by MAC address or device type or device name 3...

Страница 19: ...with parameter Format AT command parameter r n These commands are for configure certain settings Example Command AT ECHO 1 r n Response ECHO Value is 1 r n OK r n 3 Read commands Format AT command r n...

Страница 20: ...nd symbol continuously in 3 times through the serial port with 1 second time gap both before and after the 6 4 AT command list W7500S2E module serial to Ethernet module supports serial AT command for...

Страница 21: ...nt mode 0 Disable default 1 Enable DNSEN DNS for remote host R W 1 0 Disable default 1 Enable C1_CLI_IP1 Remote host IP address R W 15 Default 192 168 1 99 C1_CLI_PP1 Remote host port number R W 5 1 6...

Страница 22: ...Disable Default 1 Enable C1_LINK_T Connection Condition R W 1 Valid only in TCP client mode 0 Connect when power on default 1 Connect when receiving data from serial C1_LINK_M Send Hello Message R W 1...

Страница 23: ...onnected LISTEN Listening on TCP W CONNECT Initiate TCP connection W TCP_STATUS TCP connection status R 0 TCP closed 1 TCP connected UDP Establish UDP W SEND Send the length W 4 Range 0 2048 Default 0...

Страница 24: ...e is 1 r nOK r n In AT command mode echo on means the module could directly respond any input command line to the serial interface Thus this option may help users more easily through serial terminal s...

Страница 25: ...and cannot be null Default admin Set Response PASS Value is value r nOK r n Example Command AT PASS Admin1 r n Response PASS Value is Admin1 r nOK r n The password is used for factory reset TCP passwo...

Страница 26: ...command mode Command format Parameters Usage AT EXIT Nil Execute Response OK r n Example Command AT EXIT r n Response OK r n It will save the current settings Restart the module and make the settings...

Страница 27: ...1 r nOK r n This defines the starting mode after power on or reboot or executing the RESET command C1_OP Operating mode Command format Parameters Usage AT C1_OP Nil Read AT C1_OP parameter 0 TCP Serve...

Страница 28: ...16 254 1 maximum length of IP address is 15 bytes This value is effective only if IP configuration mode IP_MODE is in Static IP mode MARK Subnet mask Command format Parameters Usage AT MARK Nil Read...

Страница 29: ...t Parameters Usage AT C1_PORT Nil Read AT C1_PORT parameter Local port number Default 5000 Set Response C1_PORT Value is value r nOK r n Example Command AT C1_PORT 5000 r n Response C1_PORT Value is 5...

Страница 30: ...st IP address Command format Parameters Usage AT C1_CLI_IP1 Nil Read AT C1_CLI_IP1 parameter Default 192 168 1 99 Set Response C1_CLI_IP1 Value is value r nOK r n Example Command AT C1_CLI_IP1 192 168...

Страница 31: ...TIME parameter Range 0 60000 Unit ms Set Default 0 reconnect immediately Response RECONTIME Value is value r nOK r n Example Command AT RECONTIME 1000 r n Response RECONTIME Value is 1000 r nOK r n Th...

Страница 32: ...is value r nOK r n Example Command AT C1_BAUD 10 r n Response C1_BAUD Value is 10 r nOK r n C1_DATAB Data bit Command format Parameters Usage AT C1_DATAB Nil Read AT C1_DATAB parameter 0 7 bit 1 8 bit...

Страница 33: ...r nOK r n This command with parameter equal 1 enables the hardware serial flow control This may improve the data accuracy for high speed transmission Note This command with parameter equals 2 will ena...

Страница 34: ...Inactivity timeout Command format Parameters Usage AT C1_IT Nil Read AT C1_IT parameter Value range 0 60000 unit ms Default 0 disable this function Set Response C1_IT Value is value r nOK r n Example...

Страница 35: ...ving data from serial Set Response C1_LINK_T Value is value r nOK r n Example Command AT C1_LINK_T 1 r n Response C1_LINK_T Value is 1 r nOK r n This command is valid only in TCP client mode data pass...

Страница 36: ...0 4 294 967 295 Example Command AT C1_RCV_NUM r n Response C1_RCV_NUM Value is 2048 r nOK r n This command is valid for both data pass through mode AT data transfer mode NETSEND Network sent byte Com...

Страница 37: ...114 114 WEB_PORT 80 C1_PORT 5000 C1_BAUD 11 115200 C1_DATAB 1 8 C1_PARITY 0 NONE C1_STOPB 0 1 C1_SER_C 0 C1_SER_T 0 C1_SER_LEN 0 C1_CLI_IP1 192 168 1 99 C1_CLI_PP1 5000 CURRENT NAME W7500S2E Z1 PASS...

Страница 38: ...n VER Firmware version Command format Parameters Usage AT VER Nil Read Response VER Value is value r nOK r n Example Command AT VER r n Response VER Value is V1 9 r nOK r n MAC MAC address Command for...

Страница 39: ...For example http 192 168 1 88 8080 if port is 8080 Note If the module is in TCP server mode the web configuration port must be the difference to the local port number C1_PORT 6 6 AT Data transfer comm...

Страница 40: ...e After execute this command TCP connection can be monitor with the TCP_STATUS command or the voltage level of the TCP_STATUS pin This command is supported by firmware version 2 2 and above TCP_STATUS...

Страница 41: ...n status before using this command Reference to TCP_STATUS for details If this command execute successfully the serial port will get the response value The next input send to the serial port will be r...

Страница 42: ...ata from the network receiving buffer Then the module will be gone back to AT command mode If the data in the network buffer has length equal to 2 048bytes module will not receive further data If the...

Страница 43: ...r n AT C1_OP 0 r n C1_OP Value is 0 r nOK r n AT IP_MODE 0 r n IP_MODE Value is 0 r nOK r n AT IP 192 168 1 88 r n IP Value is 192 168 1 88 r nOK r n AT C1_PORT 5000 r n C1_PORT Value is 5000 r nOK r...

Страница 44: ...P_STATUS Value is 1 r nOK r n AT SEND 5 r n OK r n Serial sends data 12345 Serial receives 5 TCP server sends data abcdef AT RLEN r n RLEN Value is 6 r nOK r n AT RCV 3 r n RCV Value is 3 r nOK r n ab...

Страница 45: ...page At the address field of the browser type the IP address of your module The default IP address of WIZS2E module is 192 168 1 88 You may first search for your module IP by the ConfigTool software F...

Страница 46: ...00S2E webserver is 5 minutes After 5 minutes of inactivity re login is required Figure 7 3 Basic Settings page Network Setting Setting Description Default MAC Address MAC address of the module Not con...

Страница 47: ...r CTS RTS mode NONE Save Settings Click to save all these settings Reset Click to Restart Need to click Save Settings to apply the setting 7 3 Advance Options Figure below shows the advance settings p...

Страница 48: ...rom the Ethernet side If the password is wrong it requires re entering password until it receives a correct password Default No disable Send Hello Message Define message sent when TCP connection succe...

Страница 49: ...r new password Maximum for 15 bytes It must be numbers alphabets or the combination of both It does not accept blank as input value Confirm Password Re enter the new password Set Submit button for ren...

Страница 50: ...en click Factory Reset button to factory reset the module back to default settings 8 2 By using AT command For details of AT command default to factory reset please refer to the command DEFAULT in sec...

Страница 51: ...ure the IP address of the module needs to be in the same subnet with the host computer Then perform the steps below a Click Search b Click the designated module c Click Upload Firmware button d Choose...

Страница 52: ...solely responsible for the choice selection and use of WIZnet products and WIZnet assumes no liability for application assistance or the design of Purchasers products No license express or implied to...

Отзывы: