4.14 exit programming
Press
* to exit programming, automatically quit after 10s no operated instruction.
4.15 tamper alarm closed and opened
A, Cancel the alarm enter password to cancel the alarm temproarily.
B, Close the Tamper alarm function swipe deleted card 3 times
C, Open the Tamper alarm function swipe added card 3 times
5. Jumper Setting of access controller
5.1. J1 of active and passive output signal settings:
When 1 & 2 connected, COM NC NO used as the switch quantity output signal,
When 2 & 3 connected,shorting sircuit COM & GND as the active output signal.
5.2. J2 Reset Setting:
Short circuit J2, then power on the controller can initialized the programming code.
(Note:RESET Setting won’t wipe data )
6. Data copy
1. TXD connect RXD , RXD connect TXD to the same type access control.
2. Press copy code
* 13825256 # to the main access controller which with date.
3. The green light flashing on both of the access controller.
4. A beeping sound on the main access coontroller, it means successful operation .
7. Transformation between Access controller and card reader
7.1. Access control model( Initial setting is access control model) :
2. GLED connect to GND , 2
nd
power on the machine.
3. The green light flasing ( don’t waiting until it alarm), disconnected GLED & GND .
4. A alarm sound means the machine convert to access controller.
7.2. Card reader model (WG26 output):
1
.
D0 connect to GND , 2
power on the machine.
2. The green light flasing ( don’t waiting until it alarm), disconnected D0 & GND .
3. A alarm sound means the machine convert to WG26 card reader.
7.3. Card reader model ( WG34 output):
1
.
D1 connect to GND , 2
power on the machine.