Transport, installation, and assembly
1. Connect the spraying hose to the material
outlet on the high pressure filter (Fig. 15).
2. Connect the other end of the spraying hose
to the spray gun.
Fig. 15:
Connecting the
spraying hose to the
high pressure filter
Observe and adhere to the separate operation manual for the spray
gun.
4.3.2 Grounding the machine
WARNING
The high flow velocities during operation can result in an electrostatic
charge.
Static discharges can result in fire and explosions.
Ensure that the machine is properly grounded outside of Ex
zones!
Ensure correct grounding of the object to be coated.
The grounding point for the machine is located on the high pressure
filter.
4.3.3 Connecting the compressed air supply
To ensure the required quantity of air, the compressor output must
comply with the air requirement of the machine, and the diameter of
the air supply hoses must match the connections.
Original Operation Manual
✓
, Status:
2021/07/23
1alpg_BA_en_bb-0550010