Default Settings
The default settings are, open access mode*, when activated relay 1 on for 2 seconds, wait
time of 2 seconds, relay 2 on for 2 seconds, the default password is 123456
* Any call to the WT-2009 will activate it
Programming the WT-2009
The WT-2009 is programmed by sending it SMS text commands from a mobile phone, these
are sent to the telephone number of the SIM card installed in the WT-2009.
The password command must pre-fix all SMS text commands it is recommended the default
password be changed.
Remember that all SMS text commands must always be sent in CAPITAL LETTERS
DO NOT add spaces or any other characters
Programming Commands
If you are familiar with the commands a quick reference can be found on page 10
#PWD
Password
This command must always pre-fix any SMS text commands to the unit using the 6 digits as a password.
The unit comes from the factory with the default password set as 123456 and the following must pre-fix
all commands to the unit #PWD123456 of course when you change the password you will pre-fix all
commands with the new password
TO GATE
CONTROL
PANEL SAFETY
CONNECTION
TO GATE
CONTROL PANEL
‘START’ BUTTON
CONNECTION
Connections to an automatic gate
control panel relay 1 control the opening
of the gate relay 2 can be activated to
ensure the gate remains open, for
example a factory may want to leave
the gate open during the day for easy
access. (Note relay 1 would be
connected in series with existing safety
devices)