Administrators
Matrix
Once
you
have
programmed
in
the
administrators
numbers
it
is
now
possible
to
also
now
program
a
matrix
of
who
should
receive
the
SMS
text
alerts
and
confirmation
messages.
The
system
is
pre
‐
set
as
factory
default
to
send
#TEL1
SMS
text
alerts
and
messages
once
that
number
has
been
entered
and
confirmed
in
the
#TEL1
and
the
#CTR=
1
alarm
function
turned
On.
The
Matrix
is
programmed
using
the
#RERN
command
which
can
toggle
the
list
of
numbers
On
or
Off
based
on
using
the
digit
1
as
On
and
0
as
Off
as
follows.
The
factory
default
has
set
up
the
#RERN
as
#RERN=10000000
which
indicates
the
first
administrator
number
in
the
list
will
receive
the
SMS
text
alerts
and
messages
and
the
remaining
seven
administrators
will
not
receive
any
SMS
text
alerts
or
messages.
To
change
the
Matrix
of
persons
who
will
receive
the
SMS
alerts
or
messages
you
would
simply
use
this
format
and
to
assume
we
want
only
administrator
1
4
and
6
to
receive
the
SMS
alerts
and
messages
we
would
send
the
following
SMS
message
to
the
unit.
#PWD654321#RERN=10010100
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
RERN=10010100
and
only
the
administrators
1
4
and
6
will
receive
the
SMS
text
alerts
and
messages.
To
change
the
matrix
you
would
just
over
write
the
existing
matrix
by
sending
anther
SMS
message
to
the
unit
and
if
you
want
to
send
more
than
one
message
to
one
off
the
Administrators
you
would
simply
enter
that
administrator
in
the
#TEL
list
the
number
of
times
you
want
them
to
receive
the
SMS
text
alerts
and
messages.
Setting
up
the
Alarm
Input
Message
when
activated
The
system
has
an
alarm
Input
that
will
trigger
a
customized
SMS
text
alert
to
the
administrators
as
recorded
in
the
#TEL
list
and
activated
in
the
Matrix
to
receive
the
SMS
text
alerts.
(and
you
also
need
to
have
the
#CTR=1
alarm
function
turned
On)
This
alarm
is
activated
by
applying
a
12
Volt
DC
supply
to
the
alarm
Input
connection
for
a
period
of
5
seconds
and
to
customize
the
SMS
Message
you
would
send
the
following
SMS
Message
to
the
unit
assuming
the
required
message
is
to
be
“Gate
Forced”
#PWD654321#STR=”Gate
Forced”
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
STR:
“Gate
Forced”
and
this
SMS
Message
will
now
be
sent
to
the
administrators
from
the
#TEL
list
that
are
programmed
in
the
Matrix
to
receive
the
SMS
text
alerts.
Setting
up
the
Alarm
Input
Message
when
De
‐
activated
It
is
also
possible
to
Program
an
alarm
message
that
is
sent
when
the
alarm
Input
returns
to
normal
status
or
Alarm
Power
is
removed
and
to
set
the
following
message
as
“
Gate
locked
again”
you
would
send
the
following
message
to
the
unit.
#PWD654321#STO=”Gate
locked
again”
and
you
should
receive
the
following
SMS
message
from
the
unit
if
sent
correctly.
STR:
“Gate
locked
again”
and
this
SMS
Message
will
now
be
sent
to
the
administrators
from
the
#TEL
list
that
are
programmed
in
the
Matrix
to
receive
the
SMS
text
alerts.