4.3 Opening with key (Primor 3010) - emergency opening

• In cases of code loss or an electronic malfunction, the lock can be opened with the key.
• When the lock was opened by the key, it can only be locked by it again.
• When the lock was opened by code, it cannot be closed with the key.
• Opening with the key bypasses a programmed time delay or blocking time 

.

(The process will not be registered and cannot be read out by the PC software)

1. Insert key so that the marking on the key head is pointing towards the lock’s bolt.

2.

When using right-hand locks (turning axis towards the right) the key has to be turned clockwise. With left-hand locks 
counter-clockwise. The key lock is locked in the other direction.

3. Removing of the key is only possible when lock is closed. The key has to be turned to a tight end.

4.  When turning the key do not use force (no auxiliary means). If jamming occurs contact qualified personnel.

Index

Index

Содержание Primor 1000 Level 5

Страница 1: ...___________________3 4 2 Locking_______________________________________________________________3 4 3 Opening with key Primor 3010 emergency opening_______________________4 5 Programming the lock______...

Страница 2: ...mes stay valid Every correct input while entering the code is confirmed by an acoustic signal and flashing of the red LEDs These signals will not be considered in this instruction The red LEDs flash d...

Страница 3: ...mpanied by a long signal tone After the blocking time has passed 2 further incor rect inputs will restart the blocking time 4 2 Locking 1 Close the door at the safe and turn the handle into locking po...

Страница 4: ...ing time The process will not be registered and cannot be read out by the PC software 1 Insert key so that the marking on the key head is pointing towards the lock s bolt 2 When using right hand locks...

Страница 5: ...your new 6 digit code e g 567891 4 Re enter your new 6 digit code e g 567891 5 Programming the lock 5 1 Master and user code 5 1 1 Programming the user code programme 1 The master is able to program t...

Страница 6: ...y e g 2 minutes 02 6 Re enter the opening window e g 10 minutes 10 The time delay can be increased at any time It can be reduced only during the opening window 5 2 Time delay and opening window Only t...

Страница 7: ...lete the opening window 01 8 Delete the time delay again 00 9 Delete the opening window again 01 5 2 2 Opening with activated time delay and opening window 1 Enter your 6 digit code e g mastercode 123...

Страница 8: ...atteries in an environmentally friendly way Fig 3 Input unit Primor FL battery compartement Fig 2 Input unit Primor RO FS To change batteries open the keypad Fig 1 Input unit Primor FE To change batte...

Отзывы: