Installation instructions Gator

Rel. 1.2

6.3.4 Plug position Gator F/DF/R/DR

Cable duc B to lock

Cable duct A to lock

Audit

• Cable duc A: Standard connection to the lock.
• Cable duc B: Additional connection to the lock for generating a redundancy - activate configuration in Software GatorSelect 

and transmit via ibutton.

• Specific setting between the bus channels: The bus channel A and bus channel B of he input units can change in the foll-

wing way.  
** 



 ** 

(

 = Arrow left)   select bus channel A

** 



 ** 

= Arrow right)   select bus channel B

6.3.5 Battery compartment/cover cap

1

Gator F/DF

3

Gator R/DR

4

2

• Fig. 1: Slide the battery compartment into the input unit from above.
• Fig. 2: Fix the safety screw M4 x 16 from the side – optional.
• Fig. 3: Gator F/DF: Insert cover cap at the bottom of the input unit.
• Fig. 4: Gator R/DR: Insert turning knob and cover cap at the bottom of the input unit.

Содержание GATOR 2000

Страница 1: ..._________________________________ 6 5 Installation input unit Gator FS_____________________________________________________ 7 6 Installation input unit Gator F DF R DR_________________________________...

Страница 2: ...point out that this installation instruction is part of the VdS certification and non compliance leads to the loss of this certification By opening the lock cover warranty of the manufacturer will be...

Страница 3: ...or RO Fixing ring for input unit Cylinder screws M4 x 10 Connection axis for turnable input unit Input unit Connection cable 3 3 Panel hole Gator RO turnable 3 3 1 Spindle square 3 3 2 Spindle round T...

Страница 4: ...RO 4 x Fixing position for M4 Gator RO fixed opening for cable Drill hole min 8 mm max 11 4 mm for connection cable Gator RO turnable Hole center congruent with middle axis of nut of the electronic lo...

Страница 5: ...lock boltwork and insert grub screw M3 x 6 or arrest pin 3 5 4 Cable guidance Gator RO turnable 3 5 5 Plug position Gator RO Connection axis Audit Lock Gator PowerAdapt Gator RO turnable Lead connecti...

Страница 6: ...and has to be lead well accessible 4 Installation input unit Gator FL 4 1 Input unit Gator FL fixing on the inside 4 1 2 Input unit Gator FL fixing on the front 4 1 3 Dimensions Gator FL Emergency po...

Страница 7: ...o be drilled into the safe door From the front 2 threaded holes M5 with sufficient depth and 1 through hole opening for cable have to be drilled into the safe door Fix the input unit with the enclosed...

Страница 8: ...ut unit Gator R DR iButton reader optional iButton reader optional 6 1 2 Dimensions Gator F DF 6 1 3 Dimensions Gator R DR 14 Kabeldurchlass Opening 6 2 Axis length calculation input unit Gator R DR 6...

Страница 9: ...ews M4 From the front 4 threaded holes M4 with sufficient depth and 1 through hole opening for cable connection axis have to be drilled into the safe door Fix the input unit with the enclosed 4 screws...

Страница 10: ...setting between the bus channels The bus channel A and bus channel B of he input units can change in the foll wing way Arrow left select bus channel A Arrow right select bus channel B 6 3 5 Battery c...

Страница 11: ...Power supply via adapter Factory mode Slide DIP switch at the back of the battery compartment into illustrated position Insert 3 x 1 5 AA Alkaline batteries Slide DIP switch at the back of the battery...

Страница 12: ...t a security and functional test of the electronic lock For safety reasons it is not allowed to locate the electronic lock in the area where openings are except Gator 2000 The electronic lock has to b...

Страница 13: ...m 9 15 mm factory mode 15 mm 7 5 Mounting 7 5 1 Drill pattern Gator 2000 3000 3010 5000 6000 8000 9000 17 3 41 66 5 Gator 2000 Middle axis of nut of the electronic lock congruent with middle of the in...

Страница 14: ...ator 6000 8000 9000 GatorSignal plus 8 pin Input unit 4 pin Gator PowerAdapt GatorSignal plus 8 pin Redundanz 4 pin nput unit Gator PowerAdapt 4 pin Plug in the connection cable of the input unit in p...

Страница 15: ...C Bus address lock 00 01 02 8 3 Adjusting bus addresses input units Gator RO FL FS F DF R DR The input unit must be in full working order The bus addresses of the input unit Bus address are factory ad...

Страница 16: ...ency power supply optional insert 1 x 9V block Alkaline 9 1 Gator PowerAdapt 9 1 1 Plug position PowerAdapt 9 1 2 Drill pattern Gator PowerAdapt Connection cable Adapter 9V 78 41 36 47 5 Gator PowerAd...

Страница 17: ...m Power Adapt Power Adapt optional bus cables for redundancy Attention When there are more than 3 locks per system we recommend to use further more external power supplies This would need to be verifi...

Страница 18: ...l bus cables for redundancy Attention When there are more than 3 locks per system we recommend to use further more external power supplies This would need to be verified individually Redundancy system...

Страница 19: ...in reverse order Gator 3000 3010 The lock s bolt opens automatically has to happen easily The lock is opened Turn the handle within 20 seconds into opening position Turn the handle into locking positi...

Страница 20: ...20 Installation instructions Gator Rel 1 2...

Отзывы: