Operating manual
cyber
®
dynamic system
en-16
Doc. no.: 5022-D056658
Revision: 01
3.6.4 Environmental conditions
-
Ambient temperature during operation: 0 ... 55 °C for nominal data
-
Air humidity during operation: Relative humidity < 95 %, non-condensing
-
Installation altitude: < 2000 m above sea level without affecting performance
-
Protection class: IP 65 according to EN60529
3.7 Requirements for cables and wiring
In general, use high-quality, shielded motor and encoder cables to avoid EMC
problems.
Further requirements regarding NRTL compliance are listed in chapter 2.1.2
”.
3.8 STO safety function
The STO safety function (
S
afe
T
orque
O
ff) is used for safe torque shutdown and to reliably
protect drives from restarting. The drive system is fitted with a two-channel STO function
as standard in the basic model.
Instructions for the STO safety function can be found in the appendix
(see chapter 11
“STO safety function instructions”).