SP
+
ATEX MF
Appendix
Revision: 07
2022-D014984
en-51
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 66
Max. permissible housing temperature
[°C]
–
+80
Ambient temperature [°C]
–
see chapter 10.4 "Specifications for
Lubrication
–
synthetic gear oil (see also Chapter 7.1
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
24
5.5
5.5
5.5
5.4
5.4
32
8.7
9.7
8.6
8.6
8.5
38
9.7
9.7
9.7
9.6
9.6
a
In the case of mounting position V1, reduce the average drive speed n
1N
by 20%.
b
No-load running torques diminish during operation
c
Refers to the center of the output shaft or flange
Tbl-35: SP
+
180, 2-stage, i = 40 – 100: Technical data for use in potentially explosive atmospheres
Technical data for SP
+
180, 2-stage, i = 40 – 100
Clam-
ping
hub Ø
[mm]
Ratio i
40
50
64
70
100