2.7 General safety instructions
日本語
español
françai
s
italiano
english
deutsch
2.7
General safety instructions
Electrical connection work refers to all work on the electrical circuit for which faults and
associated hazards cannot be excluded.
Typically, plugging motor connectors into power electronics sockets in a voltage-free state is
not part of this electrical connection work.
Faulty electrical connections or not approved, current-carrying
components can cause serious injuries and even death.
Have all electrical connection work performed by trained technicians
only. The valid standards and directives must be observed for this.
Only suitable tools may be used for connection work.
Immediately replace damaged cables or plugs.
When the motor shaft is still turning or when the motor is externally
driven (generator operation), voltage is induced. This can lead to lethal
current pulses.
Ensure that no plugs or connections are exposed.
Connecting the power and signal leads under voltage (e.g. plugging
the motor connectors into the live sockets of the power electronics) is
not permitted and can lead to machine damage, serious injury or even
death.
Make sure that the motor and the motor connections of the electronics
(for power and signal) are always in a voltage-free state before
connecting.
Separation of the power and signal supply lines under voltage is not
permitted and can lead to machine damage, serious injury or even
death.
Make sure that the drive is always in a voltage-free state before
disconnecting its power and signal supply (e.g. disconnecting the motor
connectors).
Components equipped with permanent magnets and components that
feature magnetic fields can influence/impede the function of active
medical implants (e.g. pacemakers, defibrillators). This can lead to
severe injuries or even death.
Keep a sufficient distance to these components (stator, rotor) during
assembly.
If permanent magnets or permanent magnetic fields are directly
accessible (especially with rotary kit motors or the primary and
secondary parts of linear motors), you are prohibited from approaching
these motor parts.
If there are concerns, contact the manufacturer of the active medical
implants or consult
WITTENSTEIN cyber motor GmbH
.