NECTA SPA TECHNICAL MANUAL “BRIO 250”
Service Manual: Brio 250
Edition 02-2002
26
/ 27
WEEKLY CLEANING AND HYGIENE
(Expected time 6 min.)
Open the door and disconnect the
machine from the power supply (FIG
1).
Remove the powder dispensing spouts
and clean thoroughly using specific
hygiene products (FIG 3).
Remove the containers, empty them
completely and clean thoroughly (FIG.
3).
Remove the liquid collection container
(Fig. 2) and the grounds container,
empty and clean them with a sponge
damp with hot water (FIG 4).
Empty any residue from the coffee
grinder and doser assembly, clean
thoroughly and rinse with a fresh clean
sponge damp with hot water.
Remove the coffee dispensing
assembly and clean thoroughly (FIG.
6).
Remove the sugar-dispensing spout
and clean thoroughly (FIG. 7).
Remove and clean the cup shift (FIG
5).
Remove and clean the dispensing
spout assembly.
Disassemble completely the mixers
and clean thoroughly (FIG. 8).
Empty the powder collection
containers, located within the steam
suction system, and disinfect (FIG. 8).
Reassemble all parts, taking care not
to touch with your hands any parts
that come into contact with food.
Close the door and make some test
selections.
Carry out a mixer automatic wash
cycle according to the pre-set
procedures. Enter the operations
carried out in the log.
FIG.5
FIG. 2
FIG. 1
FIG.4
FIG. 8
FIG. 3
FIG. 7
FIG. 6