10
Recall Function
After switching off the hob [ 0/I ], it is possible to recall the last settings.
Cooking stages of all cooking zones (power)
Minutes and seconds of programmed cooking zone-related timers
Heat up function
Keep warm function
The recall procedure is following:
Press the key [ 0/I ]
Then press the key [ S ] within 6 seconds
The precedent settings are activated.
Bridge Function
This function allows to use the 2 cooking zones at the right at same time with the same
features as a single cooking zone. Booster
function isn’t allowed.
Action
Control panel
Display
Activate the hob
Press display [ 0/I ]
[ 0 ] or [ H ] on the
5 displays
Activate the bridge
Press on the [ + ]
rear right zone and
the [ - ] front right
[
∏ ]
Increase bridge
Press on the [ + ]
[ 1 to 9 ] or [ U ]
Stop the bridge
Press on the [ + ]
rear right zone and
the [ - ] front right
[ 0 ] or [ H ]
Control panel locking
To avoid modifying a setting of cooking zones, in particular with within the framework of
cleaning the control panel can be locked (with exception to the On/Off key [ ]).
Locking
Action
Control panel
Display
Hob locking
Press key [
] during 2s
Locking control light is on
Unlocking
Action
Control panel
Display
Hob unlocking
Press key [
] during 2s
Locking control light is off
When you start and if the locking function is on, you have 10s to unlock the hob.