![Witschi Watch Expert Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/witschi/watch-expert/watch-expert_operating-instructions-manual_990037045.webp)
6
Performing a measurement
6.1 Positioning the watch and starting a measurement automatically
Personnel:
n
Operator
Requirement:
n
The Watch Expert is switch on (
).
Positioning the watch correctly
If the watch is not positioned correctly, the test
results may be distorted.
1.
Pull the clamping jaw (Fig. 22/2) outwards.
2.
Place the watch onto the clamping area so that the crown of
the watch is positioned against the signal sensor (Fig. 22/1).
Carefully close the clamping jaw.
ð
The LED light flashes to the rhythm of the watch beats.
The measuring procedure is started.
Alternatively, the measurement can be
started via the button.
Positioning the watch in the
clamping area
Fig. 22: Microphone clamping jaw
Clamping the entire watch/clock-
work
Fig. 23: Entire watch clamped
Performing a measurement