Technical data 40-XX | 60-XX
40-XX 60-XX
Maximum elevation height
4.0 m
6.0 m
Maximum flow rate
2800 l/h
3600 l/h
Power consumption P1 (W)
4.5 - 22
4.5 - 38
Supply voltage
1 x 230V 50Hz
Sound pressure level
<43 dB(A)
EEI
≤ 0.20
Protection type
IP 42
Temperature class
TF 110
Ambient temperature
0 °C to 40 °C
Medium temperature
+5 to110 °C
System pressure
Max. 10 bar (1MPa)
Permitted media
heating water acc. to VDI 2035
Water/glycol mixture 1:1
Supply pressure
Acceptable range of application
Attention!
The use of unsuitable media can destroy the pump and injure you.
It is necessary to observe the manufacturer’s information and safety data sheets!
9
Medium Minimum
temperature
supply pressure
< 75 °C
0.05 bar 0.005 MPa 0.5 m
75 °C - 90 °C
0.3 bar
0.03 MPa
3.0 m
90 °C - 110 °C
1.1 bar
0.11 MPa
11.0 m
Temperature range at
Permissible
maximum medium
ambient temperature
temperature
25 °C
5 °C to 110 °C
40 °C
5 °C to 95 °C
Advice
Characteristic HE OEM 2 | 40-XX
H
(m)
4
3.5
3
2.5
2
1.5
1
0.5
0
0
0.5
1
1.5
2
2.5 Qm
3
/h
AUTO
CPII
CPI
PPI
PPII
SI
SII
SIII
Characteristic HE OEM 2 | 60-XX
H
(m)
6
5
4
3
2
1
0
0
0.5
1
1.5
2
2.5
3
3.5 Qm
3
/h
AUTO
CPII
CPI
PPI
PPII
SI
SII
SIII
Содержание HE OEM 2
Страница 1: ...HE OEM 2 40 XX 60 XX INSTALLATION AND OPERATING INSTRUCTIONS...
Страница 22: ...Notes 42...
Страница 23: ...Display HE Pumpen Notes 31 43...