![WiT WT901B Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/wit/wt901b/wt901b_user-manual_989784012.webp)
WT901B | manual v0707 | http://wiki.wit-motion.com/english
- 12 -
Menu of System
Button
Function
Reset
Reset to factory setting
Sleep
Sleep function (not available for Bluetooth
sensor series)
Alarm
Alarm function, not available for Bluetooth
sensor series
Algorithm
6-axis algorithm or 9-axis
Installation Direction
Vertical or horizontal installation
Instruction Start-up
Instructions sending to start-up the sensor
Instruction Start-up:
This function is used to prevent the data sent by the module after connecting to
the computer to conflict with the mouse, causing the mouse to jump. After
checking this function, the function will take effect the next time the module is
used, or it can take effect when the module is powered on again.
Menu of Calibrate
Button
Function
Acceleration
Accelerometer calibration
Magnetic Field
Magnetometer calibration
Reset Height
Reset height data to 0
(only for sensor built-in barometer,
including WT901B, WTGAHRS2, WTHARS1,
HWT901B)
Reset Z-axis Angle
Reset Z-axis angle to 0 degree, not available
for WT901B in 9-axis algorithm
Angle Reference
Setting current angle as 0 degree
Gyro Auto Calibrate
Auto-calibration of gyroscope