Rev.03
CSI16T User Manual
5
Example3: Combiner [32:1] configuration with high power transmitters:
Country power limit:10mW
Enabling external compensation on MTK952Ns, the transmitters raise power of 15dB in order to
limit to 10mW the maximum power at the output of CSA121T. Both CSI16Ts are configured at
16->1 with external combiner enabled.
Example
4
:
Ports unused and termination
To avoid wrong indications in the input led
it is necessary to terminate at 50Ω ALL THE
UNUSED PORTS related to the selected combination.
No
dummy load is required for the outputs or for ports of unused combinations.
example Combiner 4 x [4:1] with 1 unused port
Combiner 2 x [8:1] with 2 unused ports
10mW
320mW
50Ω dummy load
50Ω dummy loads