Wisperkool 20 ton Скачать руководство пользователя страница 1

             Portable Vertical

Air-Conditioning and Heating Systems

Custom HVAC & Filtration    726 Seneca Place    Madison, WI 53711    608-334-5999   [email protected]  Jan 2016

Installation and Service Manual for 20 Ton Units

82”

81”

82”

44”

82”

81”

44”

Front with Duct Kit

Side with Duct Kit

Front

Side

Back

  

726 Seneca Place   Madison, WI 53711   608-334-5999 

81”

82”

82”

Содержание 20 ton

Страница 1: ...e Vertical Air Conditioning and Heating Systems Custom HVAC Filtration 726 Seneca Place Madison WI 53711 608 334 5999 jeff wisperkool com Jan 2016 Installation and Service Manual for 20 Ton Units 82 8...

Страница 2: ...LECTRICAL COMPONENTS During installation testing servicing and troubleshooting of this product it may be necessary to work with live electrical components A qualified licensed elec trician or other in...

Страница 3: ...ty 3 Size 20 in Evaporator Coil Rows 4 Face Area 12 5 sq ft FPI 10 Condenser Coil Rows 4 Face Area 21 sq ft FPI 14 Filter Type Disposable Quantity 3 Dimensions 24in x 24 in x 2 in General Information...

Страница 4: ...Note Capacities are gross values and are not adjusted for motor heat Electric Heat Air Temperature Rise Heater kW Total MBH Temperature Rise F 45 153 5 17 7 Note Air temperature rise kW x 3413 scfm x...

Страница 5: ...WI 53711 608 334 5999 jeff wisperkool com Jan 2016 Fork Lift Pockets Warning Heavy Objects Use a forklift of suitable capacity to move the unit Failure to properly lift unit could result in death or...

Страница 6: ...sed When connecting multiple units in series do not exceed amp rating of cable used Exceeding amp ratings could cause permanent damage to the electrical cables Electrical Information Circuit Breaker Y...

Страница 7: ...WI 53711 608 334 5999 jeff wisperkool com Jan 2016 44 Side Back 81 82 82 82 81 44 82 81 44 Front with Duct Kit Side with Duct Kit Front Side 82 Line Drawings Blower Access Panel Electrical Access Pane...

Страница 8: ...oosen Tent clamps on top and sides of unit Carefully slide the sidewall fabric under the tent clamps on each side and top of the unit Tighten down the tent clamps using a 3 4 inch wrench or socket DO...

Страница 9: ...de at 72o based on the inside temperature at LOW FAN speed 5 Touch the thickest vertical bar above the screen again to run the machine at HIGH FAN speed 6 A yellow screen indicates that the machine is...

Страница 10: ...racket Retighten the 4 bolts holding the motor to the motor mount A properly tensioned belt has approximately 1 in to 1 1 2 in movement when both legs of the belt are pressed in midway between the pul...

Отзывы: