15.1. DISPLAY SCREEN MESSAGES
The controller display shows messages informing about the status of the gate, access restrictions, and errors.
Message
Flashing
Meaning
Gate status messages
cL/CL
gate closed
cL/CL
cL/CL
closing in progress
cL/CL
L
closing – slowed-down
cH/CH
stopped when closing
oP/OP
gate open
oP/OP
oP/OP
opening in progress
oP/OP
P
opening – slowed-down
oH/OH
stopped when opening
Control restriction messages
Hr
no reaction to the remote control input – Hold to Run function
oS
no reaction to the remote control input – Housing estate function
Error messages
E1
no reaction because of a motor short-circuit
E1
stopped because of a motor short-circuit
E2
no reaction because of an interruption of the optical barrier
E2
stopped because of an interruption of the optical barrier
E3
no reaction because of the active STOP input
E3
stopped because of the active STOP input
E4
no reaction because of the active 8k2 input
E4
stopped because of the active 8k2 input
E5
E5
stopped because of overload triggering
E6
no reaction because of the actuating relay failure
E7
no reaction because of the safety edge detection system failure
E8
no reaction because of the motor current measurement system failure
*The case of the first letter informs about the calibration status of the gate:
• lower case – the gate is not calibrated
• upper case – the gate is calibrated
EN
7
Technical documentation and description
+
IIiO/AWso2018/06/2018/ID-97354
Assembly and Operating Instructions
– Drive unit for gates AWso2018