- 12 -
Bedienung /
Instructions
PIDFilt
PID filter menue
FiltEMM on
if this filter set to „on“ the EMMs will be filtered
off
out and the CAT will be corrected for decrypted
programms ($)
PID-0
0x1234
PID is filtered from the TS
PID-1
0x1234
PID is filtered from the TS
PID-2
0x1234
PID is filtered from the TS
PID-3
0x1234
PID is filtered from the TS
PID-4
0x1234
PID is filtered from the TS
PID-5
0x1234
PID is filtered from the TS
PID-6
0x1234
PID is filtered from the TS
PID-7
0x1234
PID is filtered from the TS
PID-8
0x1234
PID is filtered from the TS
PID-9
0x1234
PID is filtered from the TS
PID+0
0x1234
PID is added to the TS (FiltMode =select)
PID+1
0x1234
PID is added to the TS (FiltMode =select)
PID+2
0x1234
PID is added to the TS (FiltMode =select)
PID+3
0x1234
PID is added to the TS (FiltMode =select)
PID+4
0x1234
PID is added to the TS (FiltMode =select)
PID+5
0x1234
PID is added to the TS (FiltMode =select)
PID+6
0x1234
PID is added to the TS (FiltMode =select)
PID+7
0x1234
PID is added to the TS (FiltMode =select)
PID+8
0x1234
PID is added to the TS (FiltMode =select)
PID+9
0x1234
PID is added to the TS (FiltMode =select)
* If „inactive“ displayed, the filter is not active. It is possible to select a PID in the
range from 0x0000 to 0x1fff. Is the selected value under 0x0000 the filter will
be set to „inactive“.
The inputs with leading 0x must be entered in hexadecimal format.
Should no PID filter be used, set the menu PID-0 to „inactive“.
Attention: If the settings for the input parameter „Sat-IF“ or „SymRate“ are
changed, all filter settings will be deleted and set to „inactive“.