WISI
VALUE LINE
Operating instructions
© WISI Communications GmbH & Co. KG
-20-
VX 29 B series
RF amplifier, remotely powered
4.2 Basic downstream alignment
Downstream input attenuator
HFC manager: DOWNSTREAM > Input Attenuator >
0...20 dB
0.5 dB steps
Handset:
Downstream > InputAttenuator >
Downstream input equalizer
HFC manager: DOWNSTREAM > Input Eq. > Input Eq. >
0...25 dB
0.1 dB steps
Handset:
Downstream > InputEqualizer >
HFC manager: DOWNSTREAM > Input Eq. > Cable Sim. > 0 / 5 / 10 dB
default: 0 dB
Handset:
Downstream > CableSimulator >
Downstream interstage attenuator
HFC manager: DOWNSTREAM > Interstage Atten. >
0...20 dB
0.1 dB steps
Handset:
Downstream > InterStageAtt >
Downstream interstage slope
HFC manager: DOWNSTREAM > Interstage Slope >
0...15 dB
1.0 dB steps
Handset:
Downstream > InterStageSlope >
4.3 Basic upstream alignment
Upstream input attenuator
HFC manager: UPSTREAM > Input Attenuator >
0...15 dB
0.5 dB steps
Handset:
Upstream > US InputAtt >