RF amplifier, remotely powered

4.2  Basic downstream alignment

Downstream input attenuator

HFC manager: DOWNSTREAM >  Input Attenuator >

0...20 dB
0.5 dB steps

Handset:

Downstream > InputAttenuator >

Downstream input equalizer

HFC manager: DOWNSTREAM >  Input Eq. > Input Eq. >

0...25 dB
0.1 dB steps

Handset:

Downstream > InputEqualizer >

HFC manager: DOWNSTREAM > Input Eq. > Cable Sim. > 0 / 5 / 10 dB

default: 0 dB

Handset:

Downstream > CableSimulator >

Downstream interstage attenuator

HFC manager: DOWNSTREAM >  Interstage Atten. >

0...20 dB
0.1 dB steps

Handset:

Downstream > InterStageAtt >

Downstream interstage slope

HFC manager: DOWNSTREAM >  Interstage Slope >

0...15 dB
1.0 dB steps

Handset:

Downstream > InterStageSlope >

4.3  Basic upstream alignment

Upstream input attenuator

HFC manager: UPSTREAM >  Input Attenuator >

0...15 dB
0.5 dB steps

Handset:

Upstream > US InputAtt >

Содержание 14MM-VX29B

Страница 1: ...mation on your device please visit our support website at wisiconnect tv and browse to Please read the user instructions before using the equipment WISI VALUE LINE VX 29 B series RF amplifier remotely...

Страница 2: ...n information Date Doc rev Document changes 07 07 2020 a First release FW v1 0 0 12 HFC manager v2 7 12 HFC updater v0 4 8 CE declaration of conformity Please find the declaration of conformity at our...

Страница 3: ...8 3 2 Bluetooth interface basics 9 3 3 Device control using WISI HFC manager 11 3 4 Firmware updates and recovery using WISI HFC updater 12 3 5 Remote control via FSK receiver module VT 21 16 4 Confi...

Страница 4: ...atic precautions when handling the equipment 1 2 Electrical safety Risk of bodily injury from electric shock Failure to adhere to these instructions could result in personal injury and or damage to el...

Страница 5: ...type Description ZG 27 PG 11 case connection for WISI MK 15 cable ZG 28 PG 11 adapter F female ZG 35 A PG 11 adapter 3 5 12 female Input output configuration modules see section 4 1 WISI type Descript...

Страница 6: ...ugh Output 1 Outer interfaces of the amplifier 2 3 Powering options NOTE The power supply partition of the equipment as well as all coaxial interfaces carrying remote power feeding contain dangerous v...

Страница 7: ...cording fuse Each of the the fuse sockets also allows for the forwarding of the applied device supply voltage to the corresponding RF port Spare fuses use as F1 F4 Fuse socket F1 for input Fuse socket...

Страница 8: ...not compatible Socket for handset control Position of the handset connector Handset basics Parameter menu keys Select parameter key Open parameter sub menu key Back Parameter sub menu keys Select dig...

Страница 9: ...enna enables the radio connection to a smart phone or tablet The Android app WISI HFC Manager provides the GUI for the configuration of the fiber node whereas the WISI HFC updater brings firmware upda...

Страница 10: ...Please activate the bluetooth bonding and change the key during the first setup in order to avoid unauthorized access Level 3 Access control list ACL Once paired a BT device is put on the access list...

Страница 11: ...r When starting up the application the device scan listing will populate with the active bluetooth devices nearby Device scan list example Select your device and wait for the connection to be establis...

Страница 12: ...ISI HFC updater You can use the WISI HFC updater app to update the amplifier s firmware via a bluetooth connection 3 4 1 Basic update procedure 1 When starting up the application the device scan listi...

Страница 13: ...y be available if the particular device does support FW updates via bluetooth Update screen example 5 Double check the firmware versions Maybe you want to follow the link to our support website wisico...

Страница 14: ...outcome of the update process Confirmation message example 8 Depending on your device settings you may have to re activate the bluetooth interface using the bluetooth button Then reconnect to the ampl...

Страница 15: ...to identify the device type correctly the expert mode can help recover the unit either by choosing one of the included firmware images from the select file list or by importing an update file from yo...

Страница 16: ...control via FSK receiver module VT 21 Compatible modules WISI type Description VT 21 FSK receiver module 868 MHz VT 21 B FSK receiver module 862 MHz VT 21 T FSK receiver module tunable The FSK receiv...

Страница 17: ...E WISI Communications GmbH Co KG wisi de 17 VX 29 B series RF amplifier remotely powered Operating instructions 4 Configuration of signal transmission 4 1 General signal path setup Signal transmission...

Страница 18: ...nput and output configuration WISI type Description Bridge XM 06 B Attenuator 0 dB 6 dB XM 51 B Splitter 4 dB 4 dB XM 53 B Tap 8 dB 2 dB XM 55 B Tap 13 dB 1 dB XM 56 B Tap 18 dB 1 dB XM 69 B Attenuato...

Страница 19: ...the RF output ports 1 and 2 NOTE The insertion loss of the splitters and taps will affect the maximum available downstream level at the RF ports 4 1 2 Downstream option modules WISI type Description...

Страница 20: ...0 25 dB 0 1 dB steps Handset Downstream InputEqualizer HFC manager DOWNSTREAM Input Eq Cable Sim 0 5 10 dB default 0 dB Handset Downstream CableSimulator Downstream interstage attenuator HFC manager...

Страница 21: ...amplifier s input and output signals This enables spectral monitoring of downstream signals as following and moreover the auto alignment routine section 4 5 and the automatic level and slope control A...

Страница 22: ...hannel table In order to obtain a meaningful representation of the spectrum analysis the RF channel table stored in the LR 45 should match your downstream channel lineup The channel table consists of...

Страница 23: ...alignment 1 Make sure that the ALSC mode is set to off 2 Auto Alignment functionality is reliant on the number of reference channels pilots set to two pilots 3 Choose two channels from your RF channe...

Страница 24: ...ns there will be a notification ALSC mode HFC manager ALSC ALSC Mode ALSC on ALSC off Handset ALSC Unit ALSC Mode Number of reference channels HFC manager AUTO ALIGNMENT Pilots one pilot two pilots Ha...

Страница 25: ...ssful auto alignment HFC manager AUTO ALIGN ALSC after Alignment on off Handset ALSC Unit AALIG Start Xxx ON OFF Start the auto alignment HFC manager AUTO ALIGNMENT START Handset ALSC Unit AALIG Start...

Страница 26: ...er of reference channels pilots from your RF channel lineup and set the pilot frequencies and the pilot modulation formats accordingly 4 Check the measured pilot levels at the reference frequencies Pl...

Страница 27: ...requires regulation headroom in the settings of input attenuator and slope Thus normalization will fail with a corresponding error message if attenuator and or slope settings are too close to the bou...

Страница 28: ...C on ALSC off Handset ALSC Unit ALSC Mode Pilot level deviation HFC manager ALSC Level 1 2 Dev read only Attenuator deviation HFC manager ALSC Input Att Dev read only Equalizer deviation HFC manager A...

Страница 29: ...nce Normal steady state operation fail ALSC trying to reach lock in range ALSC newly activated Insufficient level detected frozen Attenuators and equalizers fixed on last valid value 30 seconds after...

Страница 30: ...WISI VALUE LINE Operating instructions WISI Communications GmbH Co KG wisi de 30 VX 29 B series RF amplifier remotely powered space for your notes...

Страница 31: ...WISI VALUE LINE WISI Communications GmbH Co KG wisi de 31 VX 29 B series RF amplifier remotely powered Operating instructions 5 Functional diagram...

Страница 32: ...re Updates Datasheets Quick Guides Manuals Firmware Updates Known Issues List etc Entitlements for your Units after registration Forum You can discuss or share information about product configuration...