background image

English 

_19

●  

iNS
talli

N

g the rack

how to install rack

1. 

Mount the fixed or sliding shelf onto the 19-inch rack. 

See the manual provided by the manufacturer for installing the fixed shelf.

2. 

Place the recorder on the shelf and push it until the left/right fixing holes of the recorder align with the 

mounting flange holes of the 19-inch rack.

 

`

Cage nuts must be assembled in the mounting flange holes of the 19-inch rack.

Fixing holes

3. 

Insert the screws in the left/right fixing holes of the recorder to secure the recorder.

 

`

Fixing nuts and cage nuts for the recorder are not shipped with the product. They are separately sold 

at the place where you purchased the shelf or rack. 

(M6 nuts and cage nuts of head size equal to 12 mm or less are recommended.)

Содержание XRP-4210B4

Страница 1: ...Server Network Video Recorder Quick Guide XRP 4310DB4 XRP 4210B4 ...

Страница 2: ...tances this document shall be reproduced distributed or changed partially or wholly without formal authorization Disclaimer Hanwha Techwin makes the best to verify the integrity and correctness of the contents in this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Hanwha Techwin reserves the righ...

Страница 3: ...autions when installing a HDD 13 Installing the HDD installing the rack 15 15 Rack installation requirements and reference dimensions 17 Precautions when selecting shelves 18 Precautions when using sliding shelves 19 How to install rack running the product 20 20 Power 21 Setting Windows Password 23 Windows Auto Sign in Settings 25 Creating a Logical Drive 34 Create Network Teaming 38 Starting SSM ...

Страница 4: ... Do not expose internal batteries to excessive heat such as sunlight or fire There is a risk of explosion if the wrong battery type is used Only replace batteries of an identical or same type Install in a location where the power plug can be easily manipulated The power plug must be quickly unplugged in case of fire or malfunctions of the product Always use plugs that have been grounded when plugg...

Страница 5: ...is circulated through the inlet outlet as shown in the picture 3 If you pile up the products or other rack mount devices as shown in figure 2 secure room for ventilation or install a vent 4 For natural air convection place the inlet at the bottom of the rack and the outlet on top 5 It is strongly recommended that a fan motor is installed at the inlet and the outlet for air circulation Please fit a...

Страница 6: ...llowing contents in sequential order To apply with revision in a real operational environment refer to the SSM User Manual and Equipment User Manual Check Components Product Name and Function Hard Disk Installation Method How to Set Windows Password How to Create Logical Drive Running SSM and Initial Setting Guide The OS and operational software built in the product have been optimized for the har...

Страница 7: ...rew Anti slip Rubber Pad Hard Disk Number Sticker Components may look different compared to the image The type and quantity of components may differ depending on the model Components excluding the NVR main body are considered as consumables and are not included in the warranty period All manuals can be downloaded on the company website www hanwha security com ...

Страница 8: ...ion a Power It is used to turn on the power b Hard disk door lock key A security device to restrict access to the hard disk Use the key provided from purchase of product c Hard disk location display Displays the location where the hard disk is mounted d USB Used to connect USB type devices 500 mA current restriction USB 2 0 ...

Страница 9: ...he recorded video is being exported ALARM LED will light up in case of fan RAID or redundant power XRP 4310DB4 failure f Hard Disk Individual LED Lamp You can check the operation status of each hard disk by opening the front cover of the recorder Green light Hard disk mounted Flashing green light Normal RAID operating Yellow light RAID is being Degraded or Rebuilt Red light RAID cannot be recovere...

Страница 10: ...10_ overview overview Name and Function of the REAR Panel XRP 4310DB4 b e c a d g f XRP 4210B4 g f b e c a d ...

Страница 11: ...erminal to connect to power and an on off switch XRP 4210B4 b AUDIO OUT An output terminal for audio signals c HDMI 1 2 An output terminal for HDMI videos HDMI 1 Primary monitor HDMI 2 Secondary monitor d USB Used to connect USB type devices USB 3 0 supported e NETWORK 1 A port for receiving videos from cameras and connecting to a network or web viewer f NETWORK 3 g NETWORK 2 When connecting the A...

Страница 12: ...ess or miss use Cases might cause damage to HDD or recorded data To minimize the risk of data loss from a damaged HDD please backup data as often as possible If exposed to shock when disassembling or installing data stored in the hard disk may be damaged A sudden power failure or turning off the product while in HDD operation may damage the hard disk drive HDD or files stored inside may be damaged...

Страница 13: ... the cover Grab the front cover with both hands and pull it to the left to remove it 2 Press the orange button on the hard disk bracket to the left and pull forward to separate the main body and the hard disk bracket 3 Mount a HDD in the HDD bracket and screw it in using the screws provided ...

Страница 14: ...body then press and close until you hear a click Use the front cover lock key to lock the front cover so that it does not get separated If you are adding a new or previously used HDD to this product in addition to the HDD s originally installed format the new HDD manually in the set before use For replacement or installation of an additional HDD you must contact your dealer or our customer center ...

Страница 15: ...ck type 19 inch rack of EIA 310 D standard POST count 4 POST distance Depth 800 mm Dimensions of mounting flange C B A Product Product Product EIA 310 D standard mounting flange Notable dimensions Index Dimension A 450 mm 17 717 inches min B 465 mm 18 307 inches nominal C 483 4 mm 19 031 inches min installing the rack ...

Страница 16: ...mm 0 375 inches Square 44 45 mm 1 750 inches 15 90 mm 0 625 inches 15 90 mm 0 625 inches 12 7 mm 0 50 inches Recommended rack dimensions A C B D E Rack front Rack back Back mounting flange Recorder Front mounting flange Index Dimension Description A 28 mm Recorder front dimension B 560 mm Recorder product dimension C 51 mm Offset distance between mounting flange and rack front D 617 730 mm Offset ...

Страница 17: ...problem while installing the recorder make sure to select a structure where the bottom of the product is mounted For installation stability fixed shelf dedicated to 19 inch rack that supports the load of at least 30 kg is recommended A shelf needs to be secured with at least 4 screws ...

Страница 18: ...that it does not get toppled Avoid leaning on the installed product or place an object on it while its shelf is pulled out When sliding in out the shelf be careful not to drop the product Use a shelf that supports the load of at least 30 kg while it is pulled out and ensure that there is no deformation n the rail part while in use 30KG ...

Страница 19: ... recorder align with the mounting flange holes of the 19 inch rack Cage nuts must be assembled in the mounting flange holes of the 19 inch rack Fixing holes 3 Insert the screws in the left right fixing holes of the recorder to secure the recorder Fixing nuts and cage nuts for the recorder are not shipped with the product They are separately sold at the place where you purchased the shelf or rack M...

Страница 20: ... button is pressed follow the procedure below When the power supply is unstable this product may operate in a power protection mode in order to protect the product This is a function similar to that of the fuse of a circuit breaker and is not a malfunction of the product Proceed with the following measures 1 Unplug all cables connected to the back of the product When using a multi tab turn off its...

Страница 21: ...r secure use Safely store the Windows user name and password so that it is not forgotten Change the password every 3 months for security How to Set Windows Password 1 In the search bar at the bottom left of the desktop screen search Settings and click run 2 Select Accounts in Windows Settings 3 In the left menu select User Information and check the user name 4 In the left menu select Sign in Optio...

Страница 22: ...unning the product 5 In Sign in Options select Add under Password 6 In Create a password create a new password 7 When the settings are complete restart the PC and check that the new password has been applied ...

Страница 23: ...sign in is not recommended due to its vulnerability in security After setting this feature safely store the Windows user name and password so that it is not forgotten How to Set Windows Password 1 Press Windows key R and enter netplwiz in the Run window 2 After selecting the account currently in use uncheck the Users must enter a user name and password to use this computer box ...

Страница 24: ...24_ running the product running the product 3 Click Apply then OK 4 Enter the user name and password and click Apply 5 When the settings are complete restart the PC and check that the auto sign in works ...

Страница 25: ...ration or replacement of a faulty disk 1 Double click the SSM Service Manager icon on the Desktop to run 2 After clicking the Stop Service button check that the service status is Stopped If the service status is Running select Stopped 3 Run the MarvellTray program on the Desktop Or run via Start All Programs MSM MegaRAID Storage Manager StartupUI ...

Страница 26: ...er name and password M The default product User name is Administrator and there is no password 5 Check the number of mounted disks and their status in Physical Devices Status is Unconfigured 6 Click Adapter and when the sub menu appears after positioning the mouse over Operation select Create Array ...

Страница 27: ... selected disk When using RAID 5 or RAID 6 less than a maximum of 8 disks per Array is recommended for optimal product performance Use the ID below the disk image to check the location in the HDD ID Mapper 8 Run by clicking the HDD ID Mapper icon on the Desktop 9 Check the HDD location and ID in the HDD ID Mapper ...

Страница 28: ...e Size for optimal product performance Select Enable for Disk Cache for optimal product performance Playback is restricted to a maximum of 50 Mbps and 32 channels for RAID rebuild There may be a decrease in backup performance for RAID rebuild 11 Click Array select Create VD and click Submit Check the capacity in RAID Size The capacity may differ depending on the RAID Level ...

Страница 29: ...tion for all disks being used before checking Disks that have not been configured for Virtual Disk will also be displayed in the Disk Management screen For an optimal recording performance create a new simple volume only for disks that have been configured for Virtual Disk 14 When you run Windows Disk Management the Initialize Disk screen appears Select GPT GUID Partition Table to initialize the d...

Страница 30: ...ning the product running the product If the Initialize Disk screen does not appear right click on the Disk 1 area and select Initialize Disk 15 Right click on the Unallocated area and select New Simple Volume ...

Страница 31: ...lish _31 running the product 16 Click Next in the New Simple Volume Wizard 17 After checking the Simple Volume Size click Next The Simple Volume Size may differ depending on the HDD capacity and RAID Level ...

Страница 32: ... the product running the product 18 After checking the drive letter click Next 19 After changing the allocation unit size to 256K click Next Select 256K for the allocation unit size for optimal product performance ...

Страница 33: ...English _33 running the product 20 Click Finish to complete the New Simple Volume Wizard 21 Check that the disk is recognized normally ...

Страница 34: ...s below A Cisco GEC support switch using PAgP protocol B Intel Link Aggregation support switch C IEEE 802 3ad support switch 1 Connect the NETWORK 2 and NETWORK 3 ports to the network switch and LAN line respectively 2 Run Realtek Ethernet Diagnosis Utility via Start All Programs Realtek Realtek Ethernet Diagnostic Utility Or run via Task Bar Show Hidden Icons Realtek Ethernet Diagnostic Utility ...

Страница 35: ...English _35 running the product 3 Select Realtek PCIe GbE Family Controller 4 Select Teaming category 5 Click Create Team Category ...

Страница 36: ...OK A Enter the team name to use in the Team Name Category B Select either Fast Giga EtherChannel or Link Aggregation option according to use C Select both of the two adapters 7 Check that the Team has been configured M To remove the Teaming configuration click the Remove button ...

Страница 37: ...English _37 running the product 8 Use by setting the IP of the Realtek Virtual Teaming Adapter ...

Страница 38: ...er clicking the Start Service button check that the service status has changed to Started If the service status is already at Started skip this process 3 After selecting Automatically Run SSM Service on Windows Startup click Apply 4 Double click the SSM Console Icon on the Desktop to run the program Or select Start Wisenet SSM Console 5 Click Login at the sign in screen 6 Enter the default passwor...

Страница 39: ...ed and an event video in real time You can also search or play the videos saved in the server and network storage devices Search You can search and play the event logs that occurred on your devices Also by connecting to an AI camera you can play videos or search for images in various conditions such as people face vehicle vehicle number Advanced search You can search the thumbnails created at the ...

Страница 40: ...itor the status of SSM Core Server system or the registered device Configuration You can configure and manage the SSM Core Server system 3 Refer to the SSM Manual on the Desktop to view the feature of each menu and detailed method of SSM use Additional features at the top right of the SSM Console When you select Change Password from the list box you can change the password of the logged in user Wh...

Страница 41: ... input output data of the current PC Scheduled export status Displays the scheduled export action status You can set a screen lock Once button is clicked the mouse cursor will changed to a locked shape and will be set as locked To undo the locked setting click on the screen and enter the password to log in From full screen mode users can set or undo the screen locks by pressing Ctrl L You can set ...

Страница 42: ...MEMO ...

Страница 43: ...MEMO ...

Страница 44: ...l 44 1372 235663 Fax 44 1932 57 8101 www hanwha security eu Hanwha Techwin Tianjin Co Ltd Room 3F2C302 microelectronics investment service center no 1 qianxuesen road microelectronics industrial park tianjin economic and technological development area China Tel 86 400 690 6677 www hanwha security cn Hanwha Techwin Middle East FZE JAFZA View 18 20th floor office 2001 2002 2003 Downtown Jebel Ali Du...