TSW200E1
Obs.: The RX RATE shown at the OK screen is only available on hardwares K or newer.
From the OK screen, press <F3> MENU to go to the menu screen shown below:
RUNNING
BASIC ERRORS
RATES & ALARMS
HISTOGRAMS
G.821
EVENT LOG
F1 F2 F3 F4
ENTER
This screen presents the Rates & Alarms options for the Synchronous mode, but only the
Alarms option for the Asynchronous mode.
If any error or alarm occurs, the OK screen is replaced automatically by the corresponding
error or alarm screen. The OK screen becomes unavailable. From the MENU screen, the error
counters screen, alarm counters screen, histograms screen, event log screen or the ITU-T standard
G.821 screen can be reached by placing the cursor adequately and by pressing <F3> (ENTER).
Pressing <F2> (MENU) in any of these screens takes the user back to the menu.
When the CLEAR key is pressed, the test time, all counters and histograms are cleared and
the test is restarted. If the TSW200E1 was in sync, it remains in sync.
4.4 - Results Display
The results displayed during the test are:
•
many error and alarm counters