SA-x DSP Amplifier User Interface 

 

Quick Start Setup Guide for SA-8, SA-8 DSP, SA-2 DSP, SA-3 DSP  

 

Finding the SA-x DSP on the Network 

The SA-x DSP uses DHCP and mDNS to receive an IP address and be easily accessed through the local network. Be sure that the SA-x 

and your computer are on the same local network and subnet.  

 

Currently the SA-x supports Firefox, Chrome browsers on both Windows and MacOS computers, and Safari on MacOS. We 

recommend Firefox for most applications. 

 

Method One – Use Direct Connection using Ethernet without a Network or Router 

The simplest option is to connect directly without a router. By default, the SA-x will have an IP Address of 169.254.0.8. Note that you 

can only connect one (1) SA-x at a time with this method and your computer must have a wired ethernet connection. A switch (

not a 

router

) can also be used to simplify the connections. Wi-Fi cannot be used. 

 

Connect the SA-x unit to the Ethernet port of your computer by plugging an Ethernet cable from the computer directly to the SA-x 

without a router or switch. Turn on the unit and take it out of standby. 

 

Open your web browser and enter the IP Address of 

169.254.0.8/wizard.html 

to access the setup wizard. 

 

Method Two – mDNS Name 

We recommend that you connect one (1) SA-x at a time on the network if you use the mDNS Name method until you have changed 

the hostname to a unique name for the installation. 

 

NOTE:

 All SA-8 and SA-8DSP come factory default set to the Hostname “SA-8”; All SA-3 DSP are “SA-3”; All SA-2 DSP are “SA-2”. If 

you use the mDNS name with multiple amplifiers of the same model on the same network, you may not control the correct 

amplifier. Proceed with caution! 

 

1.

 

Connect the SA-x and computer to a DHCP server. It is important to be on the same subnet. 

2.

 

Power on the amplifier and open your web browser 

3.

 

System Control Page should be found 

SA-8 / SA-8 DSP = 

http://SA-8.local

 

SA-3 DSP = 

http://SA-3.local

 

SA-2 DSP = 

http://SA-2.local

  

 

Method Three – IP Scan 

This is perfect for installations with multiple SA-x on the network, or where the mDNS name is not working. 

 

NOTE: 

The Hostname may not appear correctly based on your local router settings. In this case, look for the MAC address beginning 

with 

8C:1F:64:xx:xx:xx

 

1.

 

Use 

Angry IP Scanner

 or 

Advanced IP Scanner

, or any other IP scan tool. 

2.

 

Scan the local network 

3.

 

SA-x will appear in the list 

4.

 

Enter the IP address that is shown into your browser. In the example below, 192.168.2.227 is the SA-8 

 

 

 

Содержание SA-2 DSP

Страница 1: ...n your web browser and enter the IP Address of 169 254 0 8 wizard html to access the setup wizard Method Two mDNS Name We recommend that you connect one 1 SA x at a time on the network if you use the...

Страница 2: ...ic information about the amplifier Click on the Wrench Icon to open the advanced page The first time you open the advanced page it may take a few seconds to load NOTE If this or any other page does no...

Страница 3: ...System System Log Shows the last 20 events for the system Mains Power Recovery This only applies to the SA 8 and SA 8 DSP What does the SA 8 do during an unexpected power failure Power Failure is whe...

Страница 4: ...SA X DSP QUICK START GUIDE DOCX 4 2022 11 22 Home This will populate with the routing matrix automatically as the system is programmed...

Страница 5: ...SA X DSP QUICK START GUIDE DOCX 5 2022 11 22 Inputs Custom names can be entered here for each physical input or the default names can be used...

Страница 6: ...Center etc This is not where you enter the bi amp speaker settings Name Custom Name for each channel Input Sources What are the physical inputs that will be used for input into the channel Click the...

Страница 7: ...electing the Speaker Type the system will automatically create the correct EQ and Crossover Filters for the speaker Multiple speakers can use the same Input Channel but only one speaker can use an out...

Страница 8: ...X 8 2022 11 22 Speaker testing This page can be used to send test signals to any or all of the outputs Volume level of the test tone Have you ever heard full scale pink noise from all speakers You can...

Страница 9: ...Network connection will stay active even when the SA 8 is in standby This will let the webpage still function regardless of if the SA 8 is On or in Standby Configuration DHCP is default and the curren...

Страница 10: ...ration to save a copy of the currently installed system Import Configuration loads a saved configuration NOTE This will also import network settings that may make your amplifier un reachable over the...

Страница 11: ...are registered trademarks of Wisdom Audio Wisdom Audio 1572 College Parkway Suite 164 Carson City Nevada 89706 USA Telephone 775 887 8850 Fax 775 887 8820 www wisdomaudio com SA x DSP Quick Start Gui...

Отзывы: