TReX User Manual v2.14 Firmware
RX Menu
RX
When ENABLED the TReX receiver is enabled. When DISABLED an operating current
reduction of 50mA is typical.
FREQUENCY
Specifies the receive frequency in Hz (range limited to the variant of product).
MODULATION
Specifies modulation parameters. This includes whether the modulation is 2 or 4 levels GFSK
plus the channel width. 512_25 indicates 512 baud with 25kHz channel spacing (2 level
GFSK). 9600-4L_6 indicates 9600 baud with a 6.25kHz channel spacing (4 level GFSK).
Modulation rates from 512 baud to 48K baud can be set.
PROTOCOL
Specifies the protocol to apply for serial output, accepts WTE, CUSTOM, RAW and AUX.
Other protocols may be added and supported upon request.
MODE
© WTE Limited, 2018 – Christchurch New Zealand
Page 41 of 158