13
z
Addr
6
:
set from 0000008 to 2097151. And it must key in 0 digit if disable.
Be sure to enter the “0” digit if the “disable” feature is required. Please
Do not leave it blank. Since this will cause the unit malfunction.
3. Command Password Control Set-Up
:
There are total in 4 digits’ numeric command password from 0000 to 9999.
And this programming and alternation can be set either by computer or
through the air paging messaging from the applied operator network.
4.
Customer ID Set-Up
:
Also, the customer ID contains 4 numeric digits from 0000 to 9999. And this
ID only can be set via the PC computer from your local authorized dealer. The Air
paging messages can not have any changes of this set-up.
5. Re-Program ID Set-Up
:
There are 5 digits re-program ID reserved for the authorized dealer to
alternate the unit address from the air paging. Please must make sure
These programmed digits before the air paging alternations.
6. At the Start of the Text
:
This is to distinguish each receiving messages by adding the programmed
Characters at The start of the text.
7. At the End of The Text
:
This is to distinguish each receiving messages by adding the programmed
Characters at the end of the text.
8. Power Saving Set-Up
:
“Enable” stands for the power ON-Off-ON-Off. And the “disable” means
The power output always ON.
Remark
:
This feature is reserved for the PDA operation only.
9. Baud Rate Set-Up
:
512/1200/2400 bps for Paging data speed.
10. Data Polarity Set-Up
:
Can be set by normal data or invert data polarity.
11. Message Type Set-Up
:
For numeric (4 bit) or Alphanumeric (7 bit) or Auto (not active yet) set-up.
12. Password Change Over The Air Set-Up
:
This feature is to allow users changing their current password through
The service provider’s air messages paging.
13. Address (Cap Code) Alternation Over The Air Set-Up
:
This feature is to alternate the Y1707 unit’s 7 address digits changes through
The service provider’s air messages paging.
14. Memory Select Set-Up
:
If set at the “power off all reset”, the relay’s received commands will all be
cleared out once the power off and on again. And the “keep last command
status” is to recall the last commands after the power on again.