Wirebus WCS-300 Скачать руководство пользователя страница 7

                             WCS-300

 

CAPACITIVE SENSOR 

 

WCS-300 User manual 

MAN-EN-DE-WCS300-01.00_22 

          Page 7 of 14 

All rights reserved to Wirebus © 2013 

– 2022 

 

 

Operation 

 

The WCS-300 is a capacitive proximity sensor, operates with  beat frequencies with values 

close  to  1  MHz  and  despite  the  small  power,  has  the  ease  of  propagation,  primarily  through 

metallic  bodies.  Installing  several  sensors  on  the  same  surface,  interactions  may  occur  between 

them. 

 

Besides,  the  WCS-300  detects  materials  in  direct  proportion  to  its  mass,  in  other  words,  if 

there  is  one  body  close  to  the  sensor  with  more  massive  than  the  material  to  be  measured  or 

detected,  adjustment  range  will  be  considerably  diminished,  since  the  sensor  is  on  the  verge  of 

switching. 

 

For  these  reasons,  when  the  WCS-300  is  applied  to  the  measurement,  sugarcane  level 

indication,  feed  systems  such  as  Chute-Donnelly  or  metallic  silos,  is  necessary  to  build  a  non-

metallic material area with low-mass to install it. 

 

Do  not  place  the  capacitive  sensor  directly  in  contact  with  the  part  to  be  measured.  Its 

sensitivity  is,  in  most  cases,  sufficient  to  "through"  acrylic  (or  other  non-metallic  material)  and 

detects the product. This facilitates maintenance and preventing wear of the sensing surface. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание WCS-300

Страница 1: ...User Manual CAPACITIVE SENSOR MAN EN DE WCS300 01 00_22 CAPACITIVE SENSOR WCS 300 ...

Страница 2: ...ed to the standard models and do not include special products custom 5 All precautions were taken on preparing this manual in order to guarantee the quality of its information WARNING The instrument described in this technical user manual is a device suitable for application in a specialized technical area Wirebus supplied products are submitted to a strict quality control process However industri...

Страница 3: ...ENTATION 4 TYPICAL APPLICATIONS 4 TECHNICAL SPECIFICATIONS 5 Items Included 5 HOW TO SPECIFY 5 DIMENSIONS 6 OPERATION 7 MECHANICAL INSTALLATION 8 ELECTRICAL INSTALLATION 10 WCS 300 10 WCS 300 OPT 11 ADJUSTMENT 11 WARRANTY 12 ...

Страница 4: ...adjustment wide range easy access makes it a reliable detection device with great capacity to distinguish between waste and the material to be detected The available options for output are open collector and digital voltage level Using up to 10 WCS 300 with our Converter Adder WAC 510 have an efficient Chute Donnelly level transmitter Typical Applications The WCS 300 was developed for use with can...

Страница 5: ...12 30 Vdc Electronic Unit Operating Temperature 0 C 85 C IP Protection IP 65 Construction Housing Polyamide Cover Sangel Strap Cover Polypropylene Connection Directly to the unit to be measured by flange M6 fixing kit included Aprox Weight 0 3 kg Items Included Item Description Qty 1 M6 X 20 Stainless Allen Button Head Screw Bolt 3 2 M6 Stainless Spring Washer 3 3 M6 Stainless Flat Washer 3 How to...

Страница 6: ...WCS 300 CAPACITIVE SENSOR Page 6 of 14 WCS 300 User Manual MAN EN DE WCS300 01 00_22 All rights reserved to Wirebus 2013 2022 Dimensions Figure 1 Mounting Dimensions mm ...

Страница 7: ... if there is one body close to the sensor with more massive than the material to be measured or detected adjustment range will be considerably diminished since the sensor is on the verge of switching For these reasons when the WCS 300 is applied to the measurement sugarcane level indication feed systems such as Chute Donnelly or metallic silos is necessary to build a non metallic material area wit...

Страница 8: ... Installation Figure 2 WCS 300 Installation Is recommended to use acrylic because of its characteristics such as low mass abrasion resistance of sugarcane and other materials transparency that allows viewing of the material to be detected and facilitates sensitivity adjustment possibility of use of existing displays Acrylic Metal Sensor ...

Страница 9: ...to Wirebus 2013 2022 The minimum distance between the center of the sensor and the edge of the acrylic should not be less than 100 mm Recommended is to install the SC 500 acrylic with a minimum thickness of 10 mm and a maximum thickness of 15 mm Figure 3 INCORRECT Installation Figure 4 CORRECT Installation ...

Страница 10: ... open collector and voltage level respectively with indicating color of the connection cables and a simple application example Connection Description Red RD Input Voltage Black BK Input Voltage White WH Out NPN open collector Blue BU Out PNP digital voltage level Connection examples Figure 5 NPN OC Figure 6 PNP VL P S It is recommended to install a diode to protect the internal circuitry of the eq...

Страница 11: ...K Input Voltage White WH Out Blue BU Out Connection examples Figure 7 Switching the negative pole Figure 8 Switching the positive pole P S It is recommended to install a diode to protect the internal circuitry of the equipment e g 1N4004 Adjustment The WCS 300 has a sensitivity setting located near the status light LED should be removed protective cap to access it The sensitivity must be adjusted ...

Страница 12: ... in Sertãozinho São Paulo state Brazil Wirebus s address is available at the end of this manual 4 The owner is responsible for transportation costs and risks 5 Warranty will be automatically suspended if changed are made to the equipment by personnel not authorized by Wirebus defects caused by mechanical shock exposure to conditions unfit for use or tampering with the product 6 Wirebus disclaims a...

Страница 13: ...Notes ...

Страница 14: ...0 000 Dumont São Paulo Brasil E mail vendas wirebus com br www wirebus com br MAN EN DE WCS300 01 00_22 Capacitive Sensor WCS 300 A Wirebus reserves the right to change this manual content without notice in order to keep updating it with potential product developments ...