Memory Recall

A. AUTOMATIC MEMORY

The following are automatically stored in memory for 5 minutes

following release of the power switch:

• Last reading
• Maximum reading
• Minimum reading

These readings will be displayed in the following order when

the memory switch is pressed:

• Last reading
• Maximum reading
• Minimum reading

To fill all three memory spaces, unit must operate for about 5

seconds.  If any of the above memory readings are missing,

unit must operate a few seconds longer.

B. MEMORY SELECTION

The HHSS has the capability of storing 10 extra readings in

its memory.  These readings can be obtained from the same

machine or many machines (up to 10) by pressing the memory

switch momentarily as the reading you wish stored appears on

the display. An "M" with an integer will appear on the top of

the display momentarily, and will be stored in memory. Up to

10 readings can be stored.

NOTE:

  All memory data will be erased if automatic shut-off

has occurred.  To recall a specific reading, press the memory

switch until the desired reading shows up on the display along

with its memory position.  To erase all data from the memory,

press the memory switch for at least 5 seconds until display

shows CCCCC.  If you hold the memory switch, the display

will continue to show CCCCC until the switch is released, then

will default to 0.00.

Battery Replacement

Low  battery  voltage  is

indicated by LO BAT on

the display. Remove end

cover by using a coin or

appropriate  screwdriver

and replace both batteries.

Please note polarity.

Operating Procedure

1. Run wire through the two

     wheels at the top of the

     unit (as shown). 

The HHSS may be attached to

a male disconnect on the side

with the pull pin. 

3.  Begin feeding wire through the unit. Ensure the wheels

  are turning as the wire is moving. If there is slippage,

  tighten the front tension knob to increase tension.

4.  Press  and  hold  the  on-off  switch.

  Display  will  update approximately

  every second.

5. Observe speed for as long as it is desired.

6. On-off switch must be released prior to removal of tachometer

from rotating object if last reading must be captured.

7. After release of power switch, the  last reading will be displayed

for approximately 5 minutes.  Readings will be retained in

memory for 5 minutes and can be extended any number of

additional 5 minute periods by re-pressing the memory switch.

Surface Speed Metric Conversion

Conversions such as YPM to mPM or mPM to YPM may be

obtained from the memory only by switching from one mode

to another.

2. Turn selector switch to desired unit.