Memory Recall
A. AUTOMATIC MEMORY
The following are automatically stored in memory for 5 minutes
following release of the power switch:
• Last reading
• Maximum reading
• Minimum reading
These readings will be displayed in the following order when
the memory switch is pressed:
• Last reading
• Maximum reading
• Minimum reading
To fill all three memory spaces, unit must operate for about 5
seconds. If any of the above memory readings are missing,
unit must operate a few seconds longer.
B. MEMORY SELECTION
The HHSS has the capability of storing 10 extra readings in
its memory. These readings can be obtained from the same
machine or many machines (up to 10) by pressing the memory
switch momentarily as the reading you wish stored appears on
the display. An "M" with an integer will appear on the top of
the display momentarily, and will be stored in memory. Up to
10 readings can be stored.
NOTE:
All memory data will be erased if automatic shut-off
has occurred. To recall a specific reading, press the memory
switch until the desired reading shows up on the display along
with its memory position. To erase all data from the memory,
press the memory switch for at least 5 seconds until display
shows CCCCC. If you hold the memory switch, the display
will continue to show CCCCC until the switch is released, then
will default to 0.00.
Battery Replacement
Low battery voltage is
indicated by LO BAT on
the display. Remove end
cover by using a coin or
appropriate screwdriver
and replace both batteries.
Please note polarity.
Operating Procedure
1. Run wire through the two
wheels at the top of the
unit (as shown).
The HHSS may be attached to
a male disconnect on the side
with the pull pin.
3. Begin feeding wire through the unit. Ensure the wheels
are turning as the wire is moving. If there is slippage,
tighten the front tension knob to increase tension.
4. Press and hold the on-off switch.
Display will update approximately
every second.
5. Observe speed for as long as it is desired.
6. On-off switch must be released prior to removal of tachometer
from rotating object if last reading must be captured.
7. After release of power switch, the last reading will be displayed
for approximately 5 minutes. Readings will be retained in
memory for 5 minutes and can be extended any number of
additional 5 minute periods by re-pressing the memory switch.
Surface Speed Metric Conversion
Conversions such as YPM to mPM or mPM to YPM may be
obtained from the memory only by switching from one mode
to another.
2. Turn selector switch to desired unit.
Top View
On/Off Switch
Wire Feed >
Pin for
male QD
attachment
Tension Knob >
On/Off
ELCo Enterpises, Inc. • 5750 Marathon Drive • Jackson, MI USA 49201 • (517) 782-8040 • Fax (517) 782-8039
www.wire-wizard.com