Страница 2: ... II CHARACTERS 1 Operate easily so long as the delay time the heat time and the cooling time and also the heating current switch gear is set and then rotating the disc worktable manually the time delay system the heating system and the cooling system can operate automatically and finally complete the sealing process 2 There are three worktables for the machine which accelerate the packing speed en...

Страница 3: ... Adjustable Shifting thermoelectricity device Eight adjustable channel Counting Six figures Pressure area mm 480mm 340mm Turntable area cm Φ980mm Capacity 3 7 seconds mold Qty of mold 1 set for 3 pcs produce specially Height of packing objects 2mm 150mm changeable Packing material PVC blister pieces and plastic paper card Using Air source 0 4Mpa Machine size 1080mm 980mm 1460mm Weight 150kgs ...

Страница 4: ...n the travel switch turn the AC contactor The pressure board pressurizes down side automatically The mold heating element is charged with electricity heats and cools to the fixed time finish the sealing then the pressure board returns to the position Then revolve the disc worktable to be 120 to make the second worktable to enter into the working position The three worktables can be continuous work...

Страница 5: ...me and the heating current conversion switch They are international Generally the smaller the electric and the longer the heating time the better the packing quality will be VII PRECAUTIONS AND MAINTENANCE 1 All the adjustable device must be adjusted from low to high slowly when debug the new mold which will protect the mold from damage 2 The mold should be placed on the center of working position...

Страница 6: ...on gear too high Adjust lower Burning Heating time too long Adjust shorter Cannot seal up Current conversion gear too low Adjust higher Cannot seal up Heating time too short Adjust longer Cannot seal up Card paper have no glue Stick glue on Cannot seal up The plastic material is not good Change it Mold hasn t heat Connection of the electrode under the turntable is not good Change it Mold hasn t he...

Страница 7: ...rce doesn t supply Connect the air source Pressure board has no fluctuation Air source is not enough Adjust pressure of the air source Pressure board has no fluctuation The electrical magnet valve has malfunctions Change it Pressure board has no fluctuation The blowhole is locked Adjust and clean Pressure board has no fluctuation The traveling switch has malfunctions Change it IX THE MOLDS ELECTRI...