5. Safety Instructions 

1. Place the tank horizontal when installing, do not tilt the pump. Check whether  
    the  level drop is centered; if there is tilt, adjust the water level before using it.

2. Do not place electrical appliances or valuables under the condensate pump 
    to avoid loss caused by power failure or water leakage.

3. Non - professional personnel should not install it to avoid danger.

4. The condensate pump is not waterproof. Do not place it in the open air, 
     outdoors or in a place prone to flooding.

5. The condensate pump power supply needs to be independent to maintain 
    permanent power supply. For details of connecting with air conditioning 
    system, please refer to the wiring diagram.

6. It is prohibited that the water inflow is bigger than our stated flow rate, which 
    will easily cause the motor to work continuously and fail. Instant big water 
    inflow will also cause the condensate pump fail to discharge water in time, 
    leading to water leakage.

feeling for more

6. Installation Procedure

(

1

Make sure the probe in the tank is on the right side of the filter net, the filter net and 

      the upper cover are firmly mounted on the tank. (as shown below)

(2) Make sure the tank is placed smoothly and the outlet pipe of the air conditioner is 
      tightly connected with the water pipe of tank. (as shown below) 

(3)

 

P12 Connect the vent pipe with the air hole. P12C don't need to connect

(4) Place the pump in the position beyond the ceiling. (as shown below)

05

P12

 P12C

2

3

1

A

B

4

5

Содержание P12

Страница 1: ...OPERATION MANUAL feeling for more P12 P12c CONDENSATE PUMP Compact and Flexible Silence and Durable ...

Страница 2: ...Upper cover plate Air hole φ6 20 Water pipe φ6 1500 Induction signal line Part Name Power cord Water outlet pipe Condensate pump assembly 1 1 P12 1 2 P12C No 1 2 3 4 No 5 6 7 8 No 9 10 11 Part Name Outlet port Upper cover Pump Intermediate plate Part Name Sealing ring Tank Control panel Power module Part Name Four core power cord Filter net Water inlet pipe ...

Страница 3: ...12C 12 10 8 7 6 2 0 5 10 15 20 25 30 35 40 P12 P12C 4 Flow Rate Chart P12 P12C 0m 12 12 2m 10 10 4m 8 8 6m 6 6 7m 4 4 3 Technical Data Model Performance l h head Meters head m Flow L h Model Voltage Discharge Head max Flow Rate max Tank Capacity Mini Splits up to Sound Level at 1m Ambient Temp 12L h 3 2GPH 7m 23ft 30 000btu hr 19dB A 100V 230V 50 60Hz 45ml ...

Страница 4: ...ng with air conditioning system please refer to the wiring diagram 6 It is prohibited that the water inflow is bigger than our stated flow rate which will easily cause the motor to work continuously and fail Instant big water inflow will also cause the condensate pump fail to discharge water in time leading to water leakage feeling for more 6 Installation Procedure 1 Make sure the probe in the tan...

Страница 5: ...t the discharge head is less than 6m and the length of the water pipe is less than 15m as shown below 15M 6M Insert in alignment with arrow direction Locking Alignment of locating slots 9 P12C Drainage Pump has built in alarm buzzer When the pump fails and water level reaches the alarm level the buzzer will sound om om 10 Connect the power cord insert it in the direction of arrow on the power cord...

Страница 6: ...eck the voltage 7 Troubleshooting Note Proper use and maintenance can improve the life of pump We suggest to check and clean the condensate pump before seasons changing or next year using feeling for more 11 Power supply wiring in order to avoid leakage of condensate pump please connect the alarm signal line and the Normally Closed signal terminals according to the requirements of different workin...

Отзывы: