1128500
WPC 2000 User Manual
4-16
Operation
Operating the Press in Automatic Single-stroke Mode
The Automatic Single-stroke function allows an external event to automatically initiate a
single stroke within a 30-second or 5-minute window, depending on the setting of option
switch 5 on S101 (see step 1, below). Generally, material feed is used as the signaling event.
However, other events such as part ejection or positive part transfer can be used.
There are three requirements for Automatic Single-stroke:
•
An Automatic Single-stroke switch must be installed (see Figure 5 at the end of the
manual)
•
There must be a trigger mechanism. A single-pole, double-throw (SPDT) contact (switch
or relay) or two solid-state switches (NPN, open collector) can be used.
•
Proper guarding equipment, such as a Shadow light curtain and fixed guards, must be
installed to protect personnel
If you intend to use Automatic Single-stroke, contact Wintriss Tech. Support.
To run the press in Automatic Single-stroke, first install the sensors and other components
required for this function, then do the following:
1.
Set option switch 5 on switch block S101 on the WPC 2000 Main Processor board to OFF
to select 30 seconds as the prior act timing or to ON to select 5 minutes (Switch 5 – Prior
Act Time for Automatic Stroke Modes, page 3-29).
2.
Set the selector switches as follows:
•
Stroke Select to “SINGLE STROKE”
•
Mode Select to “2-HAND”
•
Automatic to “ON”
3.
To initiate the first stroke, depress the Prior Act button–the Prior Act lamp will blink when
Prior Act is armed–then press and hold the Run/Inch palm buttons until the ram passes
bottom dead center.
The up stroke and all other strokes will be automatic.
It is not unusual for the press to pause at Top Stop. It is waiting for the “go” signal from
the external switch.
The external signal must occur after Top Stop within the time selected on switch 5 (30
seconds or 5 minutes). If WPC 2000 does not receive the signal within this period, it
assumes a problem has occurred and will not start the next stroke. If this happens, repeat
step 3.
PRESS STARTING UNEXPECTEDLY
Ensure that light curtains and other safeguards are properly installed and operating to protect
operators when using Automatic Single-stroke. Since an external trigger initiates press operation,
a stroke can occur unexpectedly.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
Содержание wpc 2000
Страница 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Страница 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Страница 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......
Страница 236: ......
Страница 237: ......
Страница 238: ......
Страница 239: ......
Страница 240: ......
Страница 241: ......
Страница 242: ......
Страница 243: ......
Страница 244: ......
Страница 245: ......
Страница 246: ......
Страница 247: ......
Страница 248: ......
Страница 249: ......
Страница 250: ......