1125100
WPC 1000 User Manual
3-8
Initialization, Setup, and Checkout
1.
Make sure the following WPC 1000 features are set correctly:
•
Option switches 1 and 2 on switch block S101 on the WPC 1000 Control board should
be set to OFF so that any Top-stop “On” Angle between 211° and 355° can be set on the
WPC 1000 display. See Figure 2-11, page 2-20 for location of the switch block and
Switches 1 and 2 – Top-stop “On” Angle Range, page 3-27 for instructions on how to
set the switches.
•
Pin #156 on the WPC 1000 Display board (see Figure 2-16, page 2-33) should not be
wired so that Top-stop in Inch is enabled (see Top-stop Bypass (Top-stop in Inch
Disabled), page 4-8).
•
Micro-inch (if you have wired this feature) should be disabled (see Wiring Micro-inch,
page 2-32).
•
Option switch 4 on switch block S101 should be set to OFF to disable the Auto
Compensated Top Stop (ACTS) feature (see Switch 4 – Enabling Auto Compensated
Top Stop (ACTS), page 3-29). ACTS compensates for increases in press speed by
adjusting the Top-stop “On” Angle backward (i.e., decreasing the “on” angle).
2.
Power down, then power up the WPC 1000 to enable the new settings.
3.
Clear the “Loc” message on the WPC 1000 display by turning the Stroke Select switch to
OFF, then to INCH.
4.
With the press in Inch mode, press the Reset/Select button until the “Top Stop Angle”
indicator is lit.
5.
Temporarily set the Top-stop “On” Angle to 211°, using the WPC Settings key switch.
Turning the key to “+” (counterclockwise) increases the angle; turning the key to “–”
(clockwise) decreases the angle.
6.
Press the Reset/Display button repeatedly until the “Angle/SPM” indicator is lit. This
action saves your Top-stop “On” Angle setting.
7.
With the press still in Inch mode and the main motor on, press and hold both Run/Inch
palm buttons until the press top-stops.
8.
Note the crankshaft angle shown in the LED display. Subtract the displayed value from
360°, then add the result to the default 211° Top-stop “On” Angle setting. This is your
calculated Top-stop “On” Angle.
If you have a variable-speed press, set the press to the slowest production speed, but not
slower than 6 SPM.
The Top-stop “On” Angle is set at the factory to 211°. If you haven’t changed the default
setting, you can skip step 5.
NOTICE
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......