SmartPAC PRO Servo User Manual
1147100
Chapter 7
– Fault Messages
191
“Fault message for red sensors “This N/C sensor is open”
Explanation:
A red sensor has actuated (i.e., is open to ground). When this message is displayed,
the angle at which the condition was detected is shown.
Remedy:
Check for the press or equipment malfunction that the sensor was supposed to
detect. If no malfunction has occurred, check for a problem with the sensor. Check
for loose or detached wiring at the DSI 2 or controller. Check for a severed wire
from the sensor to the DSI 2 or controller.
Miscellaneous Fault Messages
“The press cycle was interrupted before upper or lower limits were reached”
Explanation:
The ram is returning to its Upper Limit without having reached its Lower Limit or
returning to its Lower Limit without having reached its Upper Limit.
Remedy:
Check to see whether the upstroke or downstroke was prevented by a light curtain
interruption, the ram hitting something, etc. Verify that the Lower Limit set for
Ram Position (see page
, page 179) is a little higher than BDC, and
adjust, if necessary. Also verify that the ram Upper Limit is set a little lower than
TDC, and adjust, if necessary.
NOTICE
When the ram position at the top during clockwise movement is not the same as the top position
during counter-clockwise movement, as is often the case in a pendulum motion, make sure to set
the Upper Limit just below the lower of these two “top” positions.
“One of the sensor auto enable counters is greater than 99”
Explanation:
Normally, this fault will never occur since SmartPAC PRO Servo does not let you
enter a value greater than 99. However, this message could display if there is an
internal problem with SmartPAC PRO Servo.
Remedy:
First press RESET. If the message reappears, contact Wintriss Tech. Support.
“Loss of Communication at Address X”
Explanation:
SmartPAC PRO Servo is unable to communicate with the optional module
identified by “X” in the message (see Table 7-1).
Remedy:
Check the wiring of the specified module. If you continue to get this error message,
call Wintriss Tech. Support.
Table 7-1. Communication Errors: SmartPAC PRO Servo Option Identified by Address
Number
Message
Option Identified by Address
Loss of Communication at Address 1
AutoSetPAC, Channels 1-4
Loss of Communication at Address 2
AutoSetPAC, Channels 5-8
Содержание SmartPAC PRO Servo
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 18: ......
Страница 26: ...1147100 SmartPAC PRO Servo User Manual 26 Chapter 1 Introduction ...
Страница 30: ...1147100 SmartPAC PRO Servo User Manual 30 Chapter 2 Installation Figure 2 1 Installation Overview ...
Страница 51: ...SmartPAC PRO Servo User Manual 1147100 Chapter 2 Installation 51 Figure 2 15 Cam Outputs Board ...
Страница 70: ...1147100 SmartPAC PRO Servo User Manual 70 Chapter 3 Displays and Operating Modes ...
Страница 158: ...1147100 SmartPAC PRO Servo User Manual 158 Chapter 5 Program Mode ...
Страница 204: ......
Страница 206: ......
Страница 208: ......
Страница 210: ......
Страница 212: ......
Страница 213: ......
Страница 214: ......
Страница 215: ......
Страница 216: ......
Страница 217: ......
Страница 218: ......
Страница 219: ......
Страница 220: ......
Страница 221: ......
Страница 222: ......
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......