1146400
SFC Machine Interface (SMI 2) Installation Manual
34
Chapter 5
– System Messages
Parts Preset Reached
Displays whenever the value in the Parts Count window reaches the Parts Preset value, the
“Press Production when ready to run” message displaying beneath it (see
, below). Press
Production
to clear the message.
Planned
Displays whenever you select a downtime reason on the Forced Downtime Menu or Select
Downtime screen that is “associated” in SFC with the “Planned Downtime” machine state.
Indicates that the machine is in the “Planned Downtime” state.
Running at (cycles per min) . . . .
Displays whenever the machine is in the “Running” state. The speed of the machine in cycles
per minute is displayed to the right of the message, being refreshed based on the timing set
for the Production Rate Calculation Interval (see
Setting the Production Rate Calculation
Interval
in your user manual and
Production Settings
and
Rate Calculation
in the addendum).
Unplanned
Displays whenever you select a downtime reason on the Forced Downtime Menu or Select
Downtime screen that is “associated” in SFC with the “Unplanned Downtime” machine state.
Indicates that the machine is in the “Unplanned Downtime” state.
Messages Below the Status Line of the Main Menu
Function disabled while running
Displays for a few seconds whenever you press a button during machine operation that is not
functional when the press is running (e.g.,
Production
).
Parts count preset has been exceeded
Displays when the
Production
button has been pressed in response to the “Parts Preset
Reached” message (see
Messages on the Status Line of the Main Menu
, above) and the
machine continues to make parts. To respond to the message, stop the machine immediately.
Also displays when the
Preset Reached
button has been pressed in response to the
appearance of the Preset Reached screen (see
Using the Preset Reached Butto
n in your user
manual
).
Push Production when ready to run
Displays following SMI 2 power-up and whenever the “Parts Count Reached” message
displays (see
Messages on the Status Line of the Main Menu
, above). Press
Production
to
clear the message.
Messages on the Security Settings Screen
Invalid password entered
Displays whenever the entry on the Current Password screen is incorrect or the entry on the
Confirm Password screen is not identical to the New Password screen entry. Re-enter the
current password or new password.
Password out of range (0-9999)
Displays whenever the entry on the New Password screen exceeds “9999,” the screen’s
maximum value. Re-enter a new password, using a value in the valid range.
Содержание ShopFloorConnect SMI 2
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 14: ......
Страница 32: ...1146400 SFC Machine Interface SMI 2 Installation Manual 32 Chapter 2 Installation ...
Страница 36: ...1146400 SFC Machine Interface SMI 2 Installation Manual 36 Appendix A SFC Primary Item Discovery ...
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......