Chapter 2
Installation and Checkout
If you plan to perform optional wiring (for instance — MPCE monitor inputs or external
interrupt), refer to the section "Optional Wiring", found later in this chapter for additional
information.
immediate stop
FSD1
(1-3)
FSD2
(4-6)
STATUS
(7-9)
TB4
Figure 2-19. Relays Wired to Emergency Stop Circuit, Typical
active in all modes of operation
When wiring Shadow VI into the press circuit, you should ensure that it is active in all modes
of operation. This would include inch, single stroke, and continuous. Following this practice
will provide safety for setup personnel as well as the operator. In some cases, having
Shadow VI active in all modes may even eliminate the need for lockout during a die change.
See OSHA 1910.147 "Lockout/Tagout" for details. (Note: For PLC connections, see step
8B.)
The next set of instructions explains how to continue to wire the relays in series. Refer to the
instructions below. The corresponding wiring schematics (Figure 2) can be found at the end
of the manual.
6.
Connecting in series with Machine Emergency Stop (Figure 2):
CAUTION
TERMINAL BLOCK TB4 WIRED INCORRECTLY
Wire stop circuits to the upper level of terminal block TB4, not the lower level. If you wire to
the lower level, this could damage components on the circuit board.
Failure to comply with these instructions could result in property damage.
Refer to Figure 2 to connect the two stop relays in series with the press's emergency stop
circuit. The relays, which are labeled "FSD1" and "FSD2," are located on the upper level
of the TB4 connector on the control circuit board. The descriptions of these terminal
locations are as follows:
FSD1: Final switching device #1 (stop output relay #1)
FSD2: Final switching device #2 (stop output relay #2)
At the upper level of TB4, connect pins #2 and #6 in series with the press's stop circuits.
Do not remove the factory-installed jumper across #3 and #5.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......