Tab 11-14 Miscellaneous items (XX45NN to XX52NN)
Description
Usual oper-
ation (value
or range)
Safeguard setting
Medium / physical value / location
Signal number Func-
tion
Le-
vel
Trigger
value
De-
lay
Thrust bearing
Pad / temperature [°C] / thrust bearing
(AHEAD)
45 to 75
TE4521A
ALM
H
≥
80
0
SLD
H
≥
85
60
-
TS4521S
SHD
H
≥
90
60
Cylinder liner
Wall / temperature [°C] / each cylinder liner
aft side
≤
230
TE4801-nnC
ALM
H
≥
250
0
SLD
H
≥
270
60
Wall / temperature [°C] / each cylinder liner
fore side
≤
230
TE4841-nnC
ALM
H
≥
250
0
SLD
H
≥
270
60
Powertrain
Crankshaft / speed [% of CMCR] / crankshaft
-
ST5111-12S
SHD
H
≥
110
0
Tachometer turbocharger
Impeller shaft / overspeed [rpm] / each ABB
turbocharger
-
ST5201-nnA
ALM
H
refer to
0
Impeller shaft / overspeed [rpm] / each MHI
turbocharger
-
ST5201-nnA
ALM
H
refer to
0
1
•
for ABB A175-L34:
≥
16 000
•
for ABB A180-L34:
≥
14 140
•
for ABB A180-L35:
≥
12 860
•
for ABB A185-L34:
≥
12 690
2
•
for MHI MET60MB-U:
≥
16 170
•
for MHI MET66MB-U:
≥
14 440
•
for MHI MET71MB-U:
≥
13 350
•
for MHI MET83MB-U:
≥
11 410
X52
AA00-0000-00AAA-033B-A
Operation Manual
List of usual values and safeguard settings
Winterthur Gas & Diesel Ltd.
- 433 -
Issue 002 2018-11
Содержание X52
Страница 8: ...Page left intentionally blank 8 ...
Страница 113: ...Page left intentionally blank 113 ...
Страница 275: ...7 Installation 7 1 Installation 276 275 ...
Страница 487: ...13 Schematic diagrams 13 1 Schematic diagrams general 488 13 2 List of diagrams 494 487 ...