Winterhalter Gastronom RoMatik 150 Скачать руководство пользователя страница 3

 
 
 

89005232-05 

03/12 sch 

 
 
 

Winterhalter Gastronom GmbH 

Tettnanger Str. 72 

D-88070 Meckenbeuren 

 

4. Indicating elements 

 

The indicating elements are located at the front of the appliance. 

They enable the operator to 

monitor the water quality

 (”Purity level I, II and III”) during the water  

purification process and also serve to

 display error messages.

 

If an error message occurs, contact the 

Winterhalter after-sales service 

and quote the displayed error 

message. 

Your appliance is working 

normally

 if the indicator for 

purity level II or III

 lights up no later than 2 minutes 

after the 

commencement

 of water purification. If the indicator for purity level I lights up, this means that the 

water quality has deteriorated. 
The system then switches automatically to fault status (see error messages) and stops the purification  
process. 
 

 

5.  Operating the appliance 

Once your RoMatik 150 has been 

installed and calibrated

 by the Winterhalter service technician, it is ready 

to be put into operation. 

The RoMatik 150 is equipped with an 

electronic control system

 in order to simplify operation. During  

normal operation, there are only a few points to be observed: 

 

Observe indicating elements

 for the purity level in order to detect any deterioration in the water quality 

at an early stage. This will also affect the washing results of your dishwasher. 

 

Observe error messages

 in order to be able to notify the Winterhalter after-sales service in time and  

so avoid damage to the appliance. 
After producing purified water continuously for 15 minutes, the appliance automatically performs a  
flushing cycle. This is not an error. 

 

 

6.  Caring for the appliance 

 

Only use a 

damp cloth and no other cleaning agents 

on the RoMatik 150. Do not rinse the appliance 

with water. 

 

Check

 all 

water connections 

regularly. Condensation beneath the filter behind the front cover is not a 

sign of leakage, and can be simply wiped dry. If the ”stop” indicator lights up due to an accumulation of 
condensation, remove the mains plug after wiping and wait for 2 minutes before plugging it in again. 

 

Check

 the 

indicating elements 

regularly for error messages. 

calibration

Kalibriertaste

purification level

Reinheitsgrad

stop

on/off

filter I

I

II

III

filter II