WINTACT WT63A Скачать руководство пользователя страница 5

-07-

a. Grip tightly the unit body with your left hand; hold down 
     the battery door with your right hand thumb to open it 
     according to the arrow referring direction, as shown in 
     following figure:

b. Insert a 9V battery into battery compartment, note 
    the battery polarity, and then close the battery door, as 
    shown in following figure:

Battery Installment

-06-

Select Probe tip

2. Operation

Probe tip is used as following 3 conditions, please 
probe according to actual condition:
a. Measurement with short (S) probe tip: this probe tip
    is factory default installment, adapts in wide scope 
    vibration measurement, and obtains good response  
    value, as shown in following figure:

b. Measurement with long (L) probe tip: this probe tip is 
    packed inside the carry box, mainly adapts in narrow 
    objects or special objects field, the unit will response
    quickly, as shown in following figure:

c. Measurement without probe tip: adapts in smooth 
    object surface measurement to get stable value, as 
    shown in following figure:

Содержание WT63A

Страница 1: ...Version WT63A 0 Vibration Meter User s Manual 71680631004 WT63A 105G 190 130MM 1 0MM 20P MODEL WT63A...

Страница 2: ...omptly contact your dealer 1PCS 1PCS 1PCS 1PCS 1PCS 1PCS 1 Before use 2 Operation 3 Other items Contents Check up 01 Introduction 02 Features 02 Specifications 03 Diagram of the product 04 LCD display...

Страница 3: ...ce 10K or more earphones can be connected 9V Alkaline battery 20 A 25mA 20 hours continuous use Turns off automatically in 60 seconds 7 seconds 0 40 30 90 RH 6 9V 0 2V 67x30x183mm 182g including batte...

Страница 4: ...ent of acceleration the 2 LCD displays the acceleration unit m s 8 When take measurement of velocity the LCD displays the velocity unit mm s When taking measurement of displacement the LCD displays th...

Страница 5: ...s used as following 3 conditions please probe according to actual condition a Measurement with short S probe tip this probe tip is factory default installment adapts in wide scope vibration measuremen...

Страница 6: ...ment mode as shown in following figure Select Measurement Mode 08 m s MEAS ON Low battery indication a Press the key to turn on the unit as shown in following figure b After the entire screen displays...

Страница 7: ...m s mm s As per the to be measured and frequency of vibration structure select corresponding measurement mode Acceleration Velocity Displacement and frequency HI LO frequency Keep the key depressed w...

Страница 8: ...equency measurement mode to velocity or displacement mode the high frequency HI will be changed to low frequency LO automatically d Power turns off automatically in 60 seconds without any operation e...

Страница 9: ...nce in acceleration measurement worked with FFT signal analyzer Response db Without Accessory Accessory S Accessory L Frequency Hz LO range 15 25K 20 15 10 5 0 5 10 5 0 5 0 5 10 15 20K 15K 10K 5K Resp...

Страница 10: ...ears on the LCD you need to replace the battery immediately for details please refer figures and contents on page 9 of this manual b Remove the battery from the unit if it is not required for extended...