070223 Operations Manual SAT-520PLUS 39
1 2 3
o o o
1 2
o o
COM1/COM2 (J7 and J10)
Termination
Mode #
Description
Jumpers
TX (100)
RX (100)
TX/RX (300)
1
RS-232
1-2
N/A
N/A
N/A
2
RS-422 RTS Enable
3-4, 9-10
11-12
17-18
11-12
13-14
15-16
3
RS-422 Auto Enable
3-5, 9-10 (One node must
use TX/RX 300 Termination)
N/A
17-18
11-12
13-14
15-16
4
RS-485 RTS Enable
3-4, 7-8
11-12
N/A
11-12
13-14
15-16
5
RS-485 RTS Enable
with Echo-Back
3-4, 8-6
11-12
N/A
11-12
13-14
15-16
6
RS-485 Auto Enable
3-5, 7-8 (One node must use
TX/RX 300 Termination)
N/A
N/A
11-12
13-14
15-16
7
RS-485 Auto Enable
with Echo-Back
3-5, 8-6 (One node must use
TX/RX 300 Termination)
N/A
N/A
11-12
13-14
15-16
J12
panel b
acklight enabled
J1
+5V supplied to J8, pin 49 (Parallel I/O)