![WinSystems EBC-C384-D Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/winsystems/ebc-c384-d/ebc-c384-d_manual_987929035.webp)
140703
COM3 and COM4 Configuration Options in BIOS
1. RS-232 Mode
2. RS-422 Mode with RTS transmitter enable
3. RS-422 Mode with auto transmitter enable
4. RS-485 Mode with RTS transmitter enable
5. RS-485 Mode with RTS transmitter enable and echo back
6. RS-485 Mode with auto transmitter enable
7. RS-485 Mode with auto transmitter enable and echo back
Mode(s)
Configuration Note
2, 4, 5
Require the RTS bit (MCR Bit 1) to be set in order to transmit.
3, 6, 7
Require TX/RX(300) termination on one node.
4
Requires the RTS (MCR Bit 1) be de-asserted in order to receive.
* Each of the RS-422/RS-485 modes allow for jumper selection of transmit and/or receive termination and
biasing resistor(s). An 8-pin configuration jumper is provided for each port.
□ □
□ □
□ □
□ □
2
4
6
8
1
3
5
7
COM3 =
JP7
COM4 =
JP6
Termination Resistors
RS-422 Termination and Biasing Resistors
TX (100): Places a 100Ω Resistor across the TX+/TX- pair
3-4
RX (100): Places a 100Ω Resistor across the RX+/RX- pair
7-8
TX(300):
Places a 100Ω Resistor from +5V to TX+
1-2
Places a 100Ω Resistor between TX+ and TX-
3-4
Places a 100Ω Resistor from Ground to TX-
5-6
RS-485 Termination and Biasing Resistors
TX (100): Places a 100Ω Resistor across the TX/RX+/TX/RX- pair
3-4
TX/RX(300):
Places a 100Ω Resistor from +5V to TX/RX+
1-2
Places a 100Ω Resistor between TX/RX+ and TX/RX-
3-4
Places a 100Ω Resistor from Ground to TX/RX-
5-6