Zhengzhou Winsen Electronics Technology Co., Ltd
www.winsen-sensor.com
Tel: 86-371-67169097/67169670 Fax: 86-371-60932988 Email:
Pin Description
PIN15
Vin
(
Voltage input 5V-12V
)
PIN5
、
PIN14
GND
PIN1
VOUT(Voltage output 3.0V)
PIN3
Reserved
PIN4
Reserved
PIN7
UART (RXD) 0~3.0V Data input
PIN8
UART(TXD) 0~3.0V Data output
PIN9
Sensor analog signal
PIN10
DAC 0.4V-2V (0 - full range)
PIN2/ PIN6/ PIN11/
PIN12/ PIN13
NC
Fig 2 Pins Diagram
Communication Protocol
1. General Settings
Table 3
Baud Rate
9600
Data Bits
8
Stop Bits
1
Check Bits
Null
2. Communication Commands
There are two kinds of communication, initiative upload mode and question & answer mode. We
take initiative upload mode as the default settings. The module upload a gas concentration value
every 1S, and the command line format is as follows:
Table 4
Gas concentration value = (Byte4*256+Byte6) x 0.1
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte6
Byte 7
Byte 8
Start Byte
Gas Type
Unit
No. of
decimal
Concentration
(High Byte)
Concentration
(Low Byte)
Full Range
(High Byte)
Full Range
(Low Byte)
Check sum
0xFF
CO=0x04
ppm=0x03
1= 0x01
0x00
0x25
0x13
0x88
0x25