Winsen MQ135 Скачать руководство пользователя страница 6

 

Zhengzhou Winsen Electronics Technology Co., Ltd               

www.winsen-sensor.com

 

Tel: 86-371-67169097/67169670    Fax: 86-371-60932988                                Email: 

[email protected]

 

 

The  sensors  performance  will  be  changed  badly  if  sensors  be  sprayed  polluted  by  alkali  metals  salt 
especially brine, or be exposed to halogen such as fluorine.     

1.4 Touch water 
    Sensitivity of the sensors will be reduced when spattered or dipped in water.   

                  

1.5 Freezing           

    Do avoid icing on sensor’s surface, otherwise sensing material will be broken and lost sensitivity.             

1.6 Applied higher voltage 

Applied  voltage  on  sensor  should  not  be  higher  than  stipulated  value,  even  if  the  sensor  is  not 
physically  damaged  or  broken,  it  causes  down-line  or  heater  damaged,  and  bring  on  sensors’ 
sensitivity characteristic changed badly.   

1.7 Voltage on wrong pins 
For  6  pins  sensor,  Pin 2&5  is  heating  electrodes,  Pin  (1,3)/(4,6)  are  testing 
electrodes  (Pin  1  connects  with  Pin  3,  while  Pin  4  connects  with  Pin  6).If 
apply  voltage  on  Pin  1&3  or  4&6,  it  will  make  lead  broken;  and  no  signal 
putout if apply on pins 2&4. 

                                                                    

Fig8. Lead sketch 

2 .Following conditions must be avoided 

2.1 Water Condensation   

  Indoor  conditions,  slight  water  condensation  will  influence  sensors’  performance  lightly.  However,  if 

water condensation on sensors surface and keep a certain period, sensors’ sensitive will be decreased.

                                                          

 

2.2 Used in high gas concentration     

No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors 
characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage.                                                                                                                     

2.3 Long time storage 

  The  sensors  resistance  will  drift  reversibly  if  it’s  stored  for  long  time  without  electrify,  this  drift  is 

related  with  storage  conditions.  Sensors  should  be  stored  in  airproof  bag  without  volatile  silicon 
compound.  For  the  sensors  with  long  time  storage  but  no  electrify,  they  need  long  galvanical  aging 
time for stability before using. The suggested aging time as follow:

 

Stable2.

 

Storage Time 

Suggested aging time 

  Less than one month 

No less than 48 hours 

1 ~ 6 months 

No less than 72 hours 

More than six months 

No less than 168 hours 

 

2.4 Long time exposed to adverse environment 

  No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high 

humidity, high temperature, or high pollution etc., it will influence the sensors’ performance badly.   

2.5 Vibration 

Continual  vibration  will  result  in  sensors  down-lead  response  then  break.  In  transportation  or 
assembling line, pneumatic screwdriver/ultrasonic welding machine can lead this vibration.   

2.6 Concussion   

If sensors meet strong concussion, it may lead its lead wire disconnected.   

2.7 Usage Conditions 

2.7.1For sensor, handmade welding is optimal way. The welding conditions as follow: 

 

Содержание MQ135

Страница 1: ...Air Quality Gas Sensor Model MQ135 Manual Version 1 4 Valid from 2015 03 10 Zhengzhou Winsen Electronics Technology Co Ltd...

Страница 2: ...ance with the instructions If users disobey the terms or remove disassemble change the components inside of the sensor we shall not be responsible for the loss The specific such as color appearance si...

Страница 3: ...s in wide range and has advantages such as long lifespan low cost and simple drive circuit etc Main Applications It is widely used in domestic gas alarm industrial gas alarm and portable gas detector...

Страница 4: ...ensor Vc supplies the detect voltage to load resistance RL and it should adopts DC power Description of Sensor Characters Fig3 Typical Sensitivity Curve The ordinate is resistance ratio of the sensor...

Страница 5: ...osed to high concentration corrosive gas such as H2S SOX Cl2 HCl etc it will not only result in corrosion of sensors structure also it cause sincere sensitivity attenuation 1 3 Alkali Alkali metals sa...

Страница 6: ...eriod sensors sensitive will be decreased 2 2 Used in high gas concentration No matter the sensor is electrified or not if it is placed in high gas concentration for long time sensors characteristic w...

Страница 7: ...g the following conditions should be obey Soldering flux Rosin soldering flux contains least chlorine Speed 1 2 Meter Minute Warm up temperature 100 20 Welding temperature 250 10 One time pass wave cr...