background image

Zhengzhou Winsen Electronics Technology Co., Ltd                   

www.winsen-sensor.com

 

 

 

Tel: 86-371-67169097/67169670    Fax: 86-371-60932988                                Email: 

[email protected] 

Leading gas sensing solutions supplier in China!

 

MQ-2 Semiconductor Sensor for Flammable Gas 

 

 

Profile 

Sensitive material of MQ-2 gas sensor is SnO

2, 

which 

with lower conductivity in clean air. When the target 
flammable gas exist, the sensor’s conductivity gets 
higher along with the gas concentration rising. Users 
can convert the change of conductivity to correspond 
output signal of gas concentration through a simple 
circuit. 
MQ-2 gas sensor has high sensitivity to propane and 
smoke, also can detect the natural gas and other 
flammable steam well. It is with low cost and suitable 
for different applications of detecting kinds of 
flammable gases.

                                                          

 

Features 

It has good sensitivity to propane, smoke &etc in wide range, and has  advantages such as long lifespan, 
low cost and simple drive circuit &etc.                                                                                                                                       

Main Applications 

It is widely used in domestic gas leakage alarm, industrial flammable gas alarm    and portable gas 
detector. 

Technical Parameters                Stable.1 

Model 

MQ-2 

Sensor Type 

Semiconductor 

Standard Encapsulation 

Bakelite, Metal cap 

Target Gas 

Flammable gas, smoke 

Detection range 

300

10000ppm(flammable gas) 

Standard Circuit 

Conditions 

Loop Voltage 

V

c

 

≤24V DC 

Heater Voltage

 

V

5.0V±0.1V AC or DC 

Load Resistance

 

R

Adjustable 

Sensor character 

under standard 

test conditions 

Heater Resistance

 

R

29Ω±3Ω

room tem.

 

Heater consumption

 

P

≤950mW 

Sensitivity 

Ro(in air)/Rs(2000ppm C

3

H

8

)≥5 

Output Voltage   

Vs 

2.5V

4.0V

in 2000ppmC

3

H

8

 

Concentration Slope 

α 

≤0.6(R

3000ppm

/R

1000ppm 

C

3

H

8

Standard test 

conditions

 

Tem.    Humidity 

20

±2

℃;

55%±5%RH 

Standard test circuit 

Vc:5.0V±0.1V

 

V

H

:5.0V±0.1V 

Preheat time 

Over 48 hours 

Fig1.Sensor S

tructure 

Unit: mm

 

Содержание MQ-2

Страница 1: ...Flammable Gas Sensor Model MQ 2 Manual Version 1 4 Valid from 2015 03 10 Zhengzhou Winsen Electronics Technology Co Ltd...

Страница 2: ...ance with the instructions If users disobey the terms or remove disassemble change the components inside of the sensor we shall not be responsible for the loss The specific such as color appearance si...

Страница 3: ...e gases Features It has good sensitivity to propane smoke etc in wide range and has advantages such as long lifespan low cost and simple drive circuit etc Main Applications It is widely used in domest...

Страница 4: ...in series with sensor Vc supplies the detect voltage to load resistance RL and it should adopts DC power Description of Sensor Characters Fig3 Typical Sensitivity Curve The ordinate is resistance rat...

Страница 5: ...t 1 2 High Corrosive gas If the sensors are exposed to high concentration corrosive gas such as H2 S SOX Cl2 HCl etc it will not only result in corrosion of sensors structure also it cause sincere sen...

Страница 6: ...ight water condensation will influence sensors performance lightly However if water condensation on sensors surface and keep a certain period sensors sensitive will be decreased 2 2 Used in high gas c...

Страница 7: ...hlorine homothermal soldering iron Temperature 250 Time less than 3 seconds 2 7 1If users choose wave soldering the following conditions should be obey Soldering flux Rosin soldering flux contains lea...

Отзывы: